RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Multidetector computed tomographic angiography evaluation of micropig major systemic vessels for xenotransplantation

      한글로보기

      https://www.riss.kr/link?id=A104755037

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Due primarily to the increasing shortage of allogeneic donor organs, xenotransplantation has become the focus of a growing field of research. Currently, micropigs are the most suitable donor animal for humans. However, no standard method has been deve...

      Due primarily to the increasing shortage of allogeneic donor organs, xenotransplantation has become the focus of a growing field of research. Currently, micropigs are the most suitable donor animal for humans. However, no standard method has been developed to evaluate the systemic vascular anatomy of micropigs and standard reference values to aid in the selection of normal healthy animals as potential organ donors are lacking. Using 64-channel multidetector row computed tomographic angiography (MDCTA), we evaluated morphological features of the major systemic vessels in micropigs and compared our results to published human data. The main vasculature of the animals was similar to that of humans, except for the iliac arterial system. However, diameters of the major systemic vessels were significantly different between micropigs and humans. Specifically, the diameter of the aortic arch, abdominal aorta, external iliac artery, and femoral artery, were measured as 1.50 ± 0.07 cm, 0.85 ± 0.06 cm, 0.52 ± 0.05 cm, and 0.48 ± 0.05 cm, respectively, in the micropigs. This MDCTA data for micropig major systemic vessels can be used as standard reference values for xenotransplantation studies. The use of 64-channel MDCTA enables accurate evaluation of the major systemic vasculature in micropigs.

      더보기

      참고문헌 (Reference)

      1 Hunter P, "Xeno's paradox. Why pig cells are better for tissue transplants than human cells" 10 : 554-557, 2009

      2 Cooper DKC, "Will the pig solve the transplantation backlog" 53 : 133-147, 2002

      3 Wilmut I, "Viable offspring derived from fetal and adult mammalian cells" 385 : 810-813, 1997

      4 Murakami H, "Transgenic pigs expressing human decayaccelerating factor regulated by porcine MCP gene promoter" 61 : 302-311, 2002

      5 Machalek L, "The size of the splenic hilus, diameter of the splenic artery and its branches in the human spleen" 141 : 45-48, 1998

      6 Appel JZ 3rd, "The pig as a source of cardiac xenografts" 16 : 345-356, 2001

      7 Kahraman H, "The diameters of the aorta and its major branches in patients with isolated coronary artery ectasia" 33 : 463-468, 2006

      8 Hosenpud JD, "The Registry of the International Society for Heart and Lung Transplantation: fifteenth official report-1998" 17 : 656-668, 1998

      9 Foley WD, "Special focus session: multidetector CT: abdominal visceral imaging" 22 : 701-719, 2002

      10 Smith PA, "Role of CT angiography in the preoperative evaluation for laparoscopic nephrectomy" 18 : 589-601, 1998

      1 Hunter P, "Xeno's paradox. Why pig cells are better for tissue transplants than human cells" 10 : 554-557, 2009

      2 Cooper DKC, "Will the pig solve the transplantation backlog" 53 : 133-147, 2002

      3 Wilmut I, "Viable offspring derived from fetal and adult mammalian cells" 385 : 810-813, 1997

      4 Murakami H, "Transgenic pigs expressing human decayaccelerating factor regulated by porcine MCP gene promoter" 61 : 302-311, 2002

      5 Machalek L, "The size of the splenic hilus, diameter of the splenic artery and its branches in the human spleen" 141 : 45-48, 1998

      6 Appel JZ 3rd, "The pig as a source of cardiac xenografts" 16 : 345-356, 2001

      7 Kahraman H, "The diameters of the aorta and its major branches in patients with isolated coronary artery ectasia" 33 : 463-468, 2006

      8 Hosenpud JD, "The Registry of the International Society for Heart and Lung Transplantation: fifteenth official report-1998" 17 : 656-668, 1998

      9 Foley WD, "Special focus session: multidetector CT: abdominal visceral imaging" 22 : 701-719, 2002

      10 Smith PA, "Role of CT angiography in the preoperative evaluation for laparoscopic nephrectomy" 18 : 589-601, 1998

      11 Ezzelarab M, "Reducing Gal expression on the pig organ-a retrospective review" 12 : 278-285, 2005

      12 Ramsoondar JJ, "Production of α1,3-galactosyltransferase- knockout cloned pigs expressing human a α1,2-fucosylosyltransferase" 69 : 437-445, 2003

      13 Lai L, "Production of α-1,3-galactosyltransferase knockout pigs by nuclear transfer cloning" 295 : 1089-1092, 2002

      14 Lee MW, "Preoperative evaluation of the hepatic vascular anatomy in living liver donors: Comparison of CT angiography and MR angiography" JOHN WILEY SONS INC 24 (24): 1081-1087, 200611

      15 Tombul ST, "Preoperative evaluation of hilar vessel anatomy with 3-D computerized tomography in living kidney donors" 40 : 47-49, 2008

      16 Platt JF, "Potential renal donors: comparison of conventional imaging with helical CT" 198 : 419-423, 1996

      17 Schroeder T, "Potential living liver donors: evaluation with an all-in-one protocol with multi-detector row CT" 224 : 586-591, 2002

      18 Rankin SC, "Noninvasive imaging of living related kidney donors: evaluation with CT angiography and gadolinium-enhanced MR angiography" 177 : 349-355, 2001

      19 Tunaci A, "Multidetector row CT of the kidneys" 52 : 56-66, 2004

      20 Guven K, "Multidetector computed tomography angiography of the abdomen" 52 : 44-55, 2004

      21 Valastro M, "Multi-detector row CT scanner angiography in the evaluation of living kidney donors" 59 : 337-341, 2007

      22 Kawamoto S, "MDCT angiography of living laparoscopic renal donors" 31 : 361-373, 2006

      23 Lin CH, "Laparoscopic live donor nephrectomy in the presence of circumaortic or retroaortic left renal vein" 171 : 44-46, 2004

      24 Lerner LB, "Interactive 3-dimensional computerized tomography reconstruction in evaluation of the living renal donor" 161 : 403-407, 1999

      25 Toprak A, "Inferior vena cava diameter determines left ventricular geometry in continuous ambulatory peritoneal dialysis patients: an echocardiographic study" 18 : 2128-2133, 2003

      26 Co.kun M, "Imaging of hepatic arterial anatomy for depicting vascular variations in living related liver transplant donor candidates with multidetector computed tomography: comparison with conventional angiography" 37 : 1070-1073, 2005

      27 Radegran G, "Human femoral artery diameter in relation to knee extensor muscle mass, peak blood flow, and oxygen uptake" 278 : H162-167, 2000

      28 Lee SS, "Hepatic arteries in potential donors for living related liver transplantation: evaluation with multidetector row CT angiography" 227 : 391-399, 2003

      29 Prokop M, "General principles of MDCT" 45 (45): S4-10, 2003

      30 Inomoto T, "Experiences of 120 microsurgical reconstructions of hepatic artery in living related liver transplantation" 119 : 20-26, 1996

      31 Hager A, "Diameters of the thoracic aorta throughout life as measured with helical computed tomography" 123 : 1060-1066, 2002

      32 Niemann H, "Cytomegalovirus early promoter induced expression of hCD59 in porcine organs provides protection against hyperacute rejection" 72 : 1898-1906, 2001

      33 Cox A, "Current advances in xenotransplantation" 4 : 490-494, 2005

      34 Krejza J, "Carotid artery diameter in men and women and the relation to body and neck size" 37 : 1103-1105, 2006

      35 Ogata K, "Cardiac xenotransplantation: future and limitations" 101 : 144-155, 2004

      36 Rubin GD, "Assessment of living renal donors with spiral CT" 195 : 457-462, 1995

      37 Silveira LA, "Arterial diameter of the celiac trunk and its branches, Anatomical study" 24 : 43-47, 2009

      38 Ciccone MM, "Anteroposterior diameter of the infrarenal abdominal aorta is higher in women with polycystic ovary syndrome" 5 : 561-566, 2009

      39 Hiroshige S, "Accurate preoperative estimation of liver-graft volumetry using three-dimensional computed tomography" 75 : 1561-1564, 2003

      40 Kamel IR, "Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation" 176 : 483-487, 2001

      41 Diamond LE, "A human CD46 transgenic pig model system for the study of discordant xenotransplantation" 71 : 132-142, 2001

      42 Duong PA, "3D-multidetector CT angiography in the evaluation of potential donors for living donor lung transplantation" 20 : 17-23, 2005

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.08 0.11 0.76
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.61 0.51 0.245 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼