RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      이식 슬관정 전방십자인대의 자연 진화과정:진향적 추적 자기공며영상 = Natural Evolution of Grafted Anterior Cruciate Ligament of the Knee: Prospective Fellow-up MR Studies

      한글로보기

      https://www.riss.kr/link?id=A100883053

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To described the MR findings in the periodic changes of the size and signal intensity ofreconstructed anterior cruciate ligament (ACL) of the knee and the efficacy of oblique axial imaging in patientswho underwent arthroscopic ACL reconstruct...

      Purpose: To described the MR findings in the periodic changes of the size and signal intensity ofreconstructed anterior cruciate ligament (ACL) of the knee and the efficacy of oblique axial imaging in patientswho underwent arthroscopic ACL reconstruction using autogenous patellar tendon. Materials and Methods: Twenty-onepatients who had undergone ACL reconstruction were evaluated by follow-up MRI at postoperative 1 week, 1, 2, 3 and6 months, and 1 year, Conventional Fast-Spin-Echo (FSE) sagittal and coronal images and oblique axial images(proton density and T2-WI; VEMP TR/TE, 2000/20/70) were obtained perpendicular to the ligament, and using an ROIcurve in the intra-articular area, periodic changes in the cross-sectional area were evaluated by proton densityimaging and signal intensity by T2WI imaging. Cross-sectional morphology was categorized as either smooth, andround or notch-shaped and periodic changes in configuration were observed. In three cases, we evaluated the retearof reconstructed ACL by comparing the oblique axizl image obtained by conventional sagittal and coronal imaging.Results: The cross-sectional area and signal intensity of grafted ACL increased significantly (p<0.05) after 3months and at 1 year, respectively. Cross-sectional morphology was smooth and round in 86% of cases, and notchedin 14%, and during follow-up MR studies, no periodic changes were seen. Notch-shaped ACL and decreased perigraftsignal intensity, as seen on sagittal images, could lead to a misdiagnosis of partial tear ; on oblique axialimages, ACL and perigraft signal intensity were found to be normal. Conclusion: During the natural evolution ofgrafted ACL, cross-sectional area and signal intensity increased significantly after 3 months and at 1 year,respectively ; on follow-up MR studies, cross-sectional morphology did not change, however. Oblique axial imagingprovides important information for evaluating whether the reconstructed ACL is torn or not.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼