    Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

    한글로보기

    https://www.riss.kr/link?id=A107070923

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, insteadof waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.
    번역하기

    Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industr...

    Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, insteadof waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

    더보기

    참고문헌 (Reference)

    1 신정원, "퍼멀로이와 실리콘스틸의 적층 통한 전류센서의 선형성 및 포화도 개선" 한국센서학회 24 (24): 194-201, 2015

    2 "https://www.tta.or.kr/data/web.jsp"

    3 "http://www.nordicsemi.com"

    4 J. H. Park, "Study of automotive current sensor using hall effect of open loop type" Incheon University 2013

    5 C. Chakraborty, "Speed and current sensor fault detection and isolation technique for induction motor drive using axes transformation" 62 (62): 1943-1954, 2015

    6 F. Clarizia, "Smart meter systems for smart grid management" 1-6, 2016

    7 J. S. Han, "Smart home energy management system including renewable energy based on ZigBee and PLC" 60 (60): 198-202, 2014

    8 E. D. Lipson, "Sensory Receptors and Signal Transduction" Wiley-Liss 1-64, 2001

    9 S. C. Yang, "Saliency-based position estimation of permanent magnet synchronous machines using square-wave voltage injection with a single current sensor" 51 (51): 1561-1571, 2015

    10 M. Farrokhifar, "Real-time based approach for intelligent building energy management using dynamic price policies" 37 : 85-92, 2018

    1 신정원, "퍼멀로이와 실리콘스틸의 적층 통한 전류센서의 선형성 및 포화도 개선" 한국센서학회 24 (24): 194-201, 2015

    2 "https://www.tta.or.kr/data/web.jsp"

    3 "http://www.nordicsemi.com"

    4 J. H. Park, "Study of automotive current sensor using hall effect of open loop type" Incheon University 2013

    5 C. Chakraborty, "Speed and current sensor fault detection and isolation technique for induction motor drive using axes transformation" 62 (62): 1943-1954, 2015

    6 F. Clarizia, "Smart meter systems for smart grid management" 1-6, 2016

    7 J. S. Han, "Smart home energy management system including renewable energy based on ZigBee and PLC" 60 (60): 198-202, 2014

    8 E. D. Lipson, "Sensory Receptors and Signal Transduction" Wiley-Liss 1-64, 2001

    9 S. C. Yang, "Saliency-based position estimation of permanent magnet synchronous machines using square-wave voltage injection with a single current sensor" 51 (51): 1561-1571, 2015

    10 M. Farrokhifar, "Real-time based approach for intelligent building energy management using dynamic price policies" 37 : 85-92, 2018

    11 C. Gan, "Online sensorless position estimation for switched reluctance motors using one current sensor" 31 (31): 7248-7263, 2016

    12 E. K. Jeon, "Legislation and policy issues"

    13 A. Itzke, "Influence of the conductor position on a circular array of Hall sensors for current measurement" 66 (66): 580-585, 2019

    14 P. Kriz, "Improving indoor localization using Bluetooth low energy beacons" 2016 : 2083094(1)-2083094(1), 2016

    15 N. Castro, "Development of a contactless DC current sensor with high linearity and sensitivity based on the magnetoelectric effect" 27 (27): 065012(1)-065012(6), 2018

    16 H. Yan, "DC drift error mitigation method for three-phase current reconstruction with single Hall current sensor" 55 (55): 8100604(1)-8100604(4), 2019

    17 B. Yu, "Bluetooth Low Energy(BLE)based mobile electrocardiogram monitoring system" 763-767, 2012

    18 M. Rewienski, "A trajectory piecewise-linear approach to model order reduction and fast simulation of nonlinear circuits and micromachined devices" 22 (22): 155-170, 2003

    19 M. P. Fanti, "A simulation and control model for building energy management" 72 : 192-205, 2018

    20 S. Abdelmalek, "A novel scheme for current sensor faults diagnosis in the stator of a DFIG described by a TS fuzzy model" 91 : 680-691, 2016

    21 김장수, "3 Core-4 Winding 방식의 Closed loop 전류센서에 관한 연구" 금오공과대학교 산업대학원 2008

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2022 평가 계속평가 신청대상 (계속평가)
    2021-12-01 등재 등재후보로 하락 (재인증) KCI등재후보
    2018-01-01 등재 등재학술지 선정 (계속평가) KCI등재
    2017-12-01 등재 등재후보로 하락 (계속평가) KCI등재후보
    2013-01-01 등재 등재 1차 FAIL (등재유지) KCI등재
    2010-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2008-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2005-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2004-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2002-07-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.22 0.22 0.16
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.15 0.13 0.319 0.07
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼