Recently, there has been growing concern regarding healthy therefore a comfortable indoor environment has become increasingly important too. Introduction of ecological concept house the interest on the ecological architecture as an alternative plan to...
Recently, there has been growing concern regarding healthy therefore a comfortable indoor environment has become increasingly important too. Introduction of ecological concept house the interest on the ecological architecture as an alternative plan to cope with critical situation in environment. This study investigated the heating performance of box-typed double skin system applied in K R&D center. And estimate the U'-value and suggest a data base for the design. There are various kinds of double skin facade and they are applied in Europe and Japan. The researches progress actively and put to practical use within the country, too. But a great part of them are multi-story facade, therefore it need to study various kinds of double skin facade system.
The results of this study are as follows. The Urvalue is 2.0~2.9W/㎡K in summer and 1.6~1.7W/㎡K in winter by operation methods. It is distinguished than a regular double glazing and extremely excellent in winter.