      Jailing Technique Using a Catheter-based Open-cell Stent System in Internal Carotid Artery Sidewall Aneurysms Unfeasible to Simple Coiling

      한글로보기

      https://www.riss.kr/link?id=A104756405

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective:An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with t...

      Objective:An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with the Neuroform EZ stent system.
      Methods:The jailing technique using the open-cell stent system of the Neuroform EZ stent was planned in 22 consecutive patients with 22 cerebral aneurysms. We retrospectively evaluated the technical success of the jailing technique and the occurrence of interference between two microcatheters as well as the factors influencing this interference.
      Results:The jailing technique was successful in 19/22 patients(86.4%), and interference between two microcatheters occurred in 6/21(28.6%). The jailing technique failed in 3/22 patients, with problems that included failure of the stent delivery system to advance into the positioned microcatheter in one, interference between the microcatheters during the advancement of the stent delivery system in one, and failure of microcatheter insertion into the aneurysm sac in the remaining patient. Interference between the two microcatheters developed during the advance of the stent delivery system into the positioned microcatheter in all cases. One factor that influences interference between two microcatheters more than expected by chance is the carotid siphon angle (p = 0.019).
      Conclusion:The acuteness of the carotid siphon angle influences the interference between two microcatheters. Therefore, the jailing technique using the Neuroform EZ stent should be performed carefully in cerebral aneurysms with an acute carotid siphon angle because the procedure may possibly fail.

      더보기

      참고문헌 (Reference)

      1 Wajnberg E, "Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms" 72 (72): 612-619, 2009

      2 Heller RS, "Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling" 32 (32): 1714-1720, 2011

      3 Biondi A, "Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up" 61 (61): 460-468, 2007

      4 Heller RS, "Crescent sign on magnetic resonance angiography revealing incomplete stent apposition: Correlation with diffusion-weighted changes in stent-mediated coil embolization of aneurysms" 115 (115): 624-632, 2011

      5 Spiotta AM, "Comparison of techniques for stent assisted coil embolization of aneurysms" 4 (4): 339-344, 2012

      1 Wajnberg E, "Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms" 72 (72): 612-619, 2009

      2 Heller RS, "Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling" 32 (32): 1714-1720, 2011

      3 Biondi A, "Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up" 61 (61): 460-468, 2007

      4 Heller RS, "Crescent sign on magnetic resonance angiography revealing incomplete stent apposition: Correlation with diffusion-weighted changes in stent-mediated coil embolization of aneurysms" 115 (115): 624-632, 2011

      5 Spiotta AM, "Comparison of techniques for stent assisted coil embolization of aneurysms" 4 (4): 339-344, 2012

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 계속평가 신청대상 (계속평가)
      2021-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2020-12-01 평가 등재후보 탈락 (계속평가)
      2019-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2016-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2014-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2013-12-01 평가 등재후보 탈락 (등재후보2차)
      2012-03-21 학술지명변경 한글명 : 대한뇌혈관외과학회지 -> Journal of Cerebrovascular and Endovascular Neurosurgery
      외국어명 : Korean Journal of Cerebrovascular Surgery -> Journal of Cerebrovascular and Endovascular Neurosurgery
      KCI등재후보
      2012-01-01 평가 등재후보 1차 FAIL (기타) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.1 0.1 0.14
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.13 0.1 0.394 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼