This Study is performed on the numerical predictions for heat and smoke flow through different ventilation conditions for the subway fires. Door-closed situation, one side door-opened situation and both side door-opened situation were compared. Somke ...
This Study is performed on the numerical predictions for heat and smoke flow through different ventilation conditions for the subway fires. Door-closed situation, one side door-opened situation and both side door-opened situation were compared. Somke temperature, carbon monoxide concentration are analyzed.