RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques

      한글로보기

      https://www.riss.kr/link?id=A104531431

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Perfusion is a fundamental biological function that refers to the delivery of oxygen and nutrients to tissue by means of blood flow. Perfusion MRI is sensitive to microvasculature and has been applied in a wide variety of clinical applications, includ...

      Perfusion is a fundamental biological function that refers to the delivery of oxygen and nutrients to tissue by means of blood flow. Perfusion MRI is sensitive to microvasculature and has been applied in a wide variety of clinical applications, including the classification of tumors, identification of stroke regions, and characterization of other diseases. Perfusion MRI techniques are classified with or without using an exogenous contrast agent. Bolus methods, with injections of a contrast agent, provide better sensitivity with higher spatial resolution, and are therefore more widely used in clinical applications. However, arterial spin-labeling methods provide a unique opportunity to measure cerebral blood flow without requiring an exogenous contrast agent and have better accuracy for quantification. Importantly, MRI-based perfusion measurements are minimally invasive overall, and do not use any radiation and radioisotopes. In this review, we describe the principles and techniques of perfusion MRI. This review summarizes comprehensive updated knowledge on the physical principles and techniques of perfusion MRI.

      더보기

      다국어 초록 (Multilingual Abstract)

      Perfusion is a fundamental biological function that refers to the delivery of oxygen and nutrients to tissue by means of blood flow. Perfusion MRI is sensitive to microvasculature and has been applied in a wide variety of clinical applications, includ...

      Perfusion is a fundamental biological function that refers to the delivery of oxygen and nutrients to tissue by means of blood flow. Perfusion MRI is sensitive to microvasculature and has been applied in a wide variety of clinical applications, including the classification of tumors, identification of stroke regions, and characterization of other diseases. Perfusion MRI techniques are classified with or without using an exogenous contrast agent. Bolus methods, with injections of a contrast agent, provide better sensitivity with higher spatial resolution, and are therefore more widely used in clinical applications. However, arterial spin-labeling methods provide a unique opportunity to measure cerebral blood flow without requiring an exogenous contrast agent and have better accuracy for quantification. Importantly, MRI-based perfusion measurements are minimally invasive overall, and do not use any radiation and radioisotopes. In this review, we describe the principles andtechniques of perfusion MRI. This review summarizes comprehensive updated knowledge on the physical principles and techniques of perfusion MRI.

      더보기

      참고문헌 (Reference)

      1 Talagala SL, "Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil" 52 : 131-140, 2004

      2 Kim T, "Whole brain perfusion measurements using arterial spin labeling with multiband acquisition" 70 : 1653-1661, 2013

      3 Paulson OB, "Water filtration and diffusion across the blood brain barrier in man" 64 : 492-493, 1977

      4 Wong EC, "Vessel-encoded arterial spin-labeling using pseudocontinuous tagging" 58 : 1086-1091, 2007

      5 Wong EC, "Velocity-selective arterial spin labeling" 55 : 1334-1341, 2006

      6 Willats L, "Validating a local Arterial Input Function method for improved perfusion quantification in stroke" 31 : 2189-2198, 2011

      7 Larkman DJ, "Use of multicoil arrays for separation of signal from multiple slices simultaneously excited" 13 : 313-317, 2001

      8 Buckley DL, "Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI" 47 : 601-606, 2002

      9 송용섭, "True Progression versus Pseudoprogression in the Treatment of Glioblastomas: A Comparison Study of Normalized Cerebral Blood Volume and Apparent Diffusion Coefficient by Histogram Analysis" 대한영상의학회 14 (14): 662-672, 2013

      10 Kiselev VG, "Transverse relaxation effect of MRI contrast agents: a crucial issue for quantitative measurements of cerebral perfusion" 22 : 693-696, 2005

      1 Talagala SL, "Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil" 52 : 131-140, 2004

      2 Kim T, "Whole brain perfusion measurements using arterial spin labeling with multiband acquisition" 70 : 1653-1661, 2013

      3 Paulson OB, "Water filtration and diffusion across the blood brain barrier in man" 64 : 492-493, 1977

      4 Wong EC, "Vessel-encoded arterial spin-labeling using pseudocontinuous tagging" 58 : 1086-1091, 2007

      5 Wong EC, "Velocity-selective arterial spin labeling" 55 : 1334-1341, 2006

      6 Willats L, "Validating a local Arterial Input Function method for improved perfusion quantification in stroke" 31 : 2189-2198, 2011

      7 Larkman DJ, "Use of multicoil arrays for separation of signal from multiple slices simultaneously excited" 13 : 313-317, 2001

      8 Buckley DL, "Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI" 47 : 601-606, 2002

      9 송용섭, "True Progression versus Pseudoprogression in the Treatment of Glioblastomas: A Comparison Study of Normalized Cerebral Blood Volume and Apparent Diffusion Coefficient by Histogram Analysis" 대한영상의학회 14 (14): 662-672, 2013

      10 Kiselev VG, "Transverse relaxation effect of MRI contrast agents: a crucial issue for quantitative measurements of cerebral perfusion" 22 : 693-696, 2005

      11 Yang Y, "Transit time, trailing time, and cerebral blood flow during brain activation: measurement using multislice, pulsed spin-labeling perfusion imaging" 44 : 680-685, 2000

      12 Wu O, "Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix" 50 : 164-174, 2003

      13 Kim J, "Toward fully automated processing of dynamic susceptibility contrast perfusion MRI for acute ischemic cerebral stroke" 98 : 204-213, 2010

      14 Robson PM, "Time-resolved vessel-selective digital subtraction MR angiography of the cerebral vasculature with arterial spin labeling" 257 : 507-515, 2010

      15 Saver JL, "Time is brain--quantified" 37 : 263-266, 2006

      16 Kidwell CS, "Thrombolytic reversal of acute human cerebral ischemic injury shown by diffusion/perfusion magnetic resonance imaging" 47 : 462-469, 2000

      17 Calamante F, "The physiological significance of the time-to-maximum (Tmax) parameter in perfusion MRI" 41 : 1169-1174, 2010

      18 Kety SS, "The nitrous oxide method for the quantitative determination of cerebral blood flow in man: theory, procedure and normal values" 27 : 476-483, 1948

      19 Willats L, "The 39 steps: evading error and deciphering the secrets for accurate dynamic susceptibility contrast MRI" 26 : 913-931, 2013

      20 Bjornerud A, "T1- and T2*-dominant extravasation correction in DSC-MRI: part I--theoretical considerations and implications for assessment of tumor hemodynamic properties" 31 : 2041-2053, 2011

      21 Helle M, "Superselective pseudocontinuous arterial spin labeling" 64 : 777-786, 2010

      22 Günther M, "Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements" 54 : 491-498, 2005

      23 Kim EJ, "Simultaneous acquisition of perfusion and permeability from corrected relaxation rates with dynamic susceptibility contrast dual gradient echo" 22 : 307-314, 2004

      24 Jahng GH, "Sensitive and fast T1 mapping based on two inversion recovery images and a reference image" 32 : 1524-1528, 2005

      25 Jackson A, "Semi-quantitative parameter analysis of DCE-MRI revisited: monte-carlo simulation, clinical comparisons, and clinical validation of measurement errors in patients with type 2 neurofibromatosis" 9 : e90300-, 2014

      26 Silver MS, "Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equation" 31 : 2753-2755, 1985

      27 Davies NP, "Selective arterial spin labeling (SASL): perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses" 49 : 1133-1142, 2003

      28 Pintaske J, "Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla" 41 : 213-221, 2006

      29 Asllani I, "Regression algorithm correcting for partial volume effects in arterial spin labeling MRI" 60 : 1362-1371, 2008

      30 Kim SM, "Regional cerebral perfusion in patients with Alzheimer’s disease and mild cognitive impairment: effect of APOE epsilon4 allele" 55 : 25-34, 2013

      31 Brix G, "Regional blood flow, capillary permeability, and compartmental volumes: measurement with dynamic CT--initial experience" 210 : 269-276, 1999

      32 Alsop DC, "Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow" 16 : 1236-1249, 1996

      33 Alsop DC, "Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia" 2014

      34 Straka M, "Real-time diffusion-perfusion mismatch analysis in acute stroke" 32 : 1024-1037, 2010

      35 Pruessmann KP, "RF pulse concatenation for spatially selective inversion" 146 : 58-65, 2000

      36 Wong EC, "Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)" 39 : 702-708, 1998

      37 Waldman AD, "Quantitative imaging biomarkers in neuro-oncology" 6 : 445-454, 2009

      38 Shin W, "Quantitative cerebral perfusion using dynamic susceptibility contrast MRI: evaluation of reproducibility and age- and gender-dependence with fully automatic image postprocessing algorithm" 58 : 1232-1241, 2007

      39 Bonekamp D, "Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography" 66 : 57-66, 2011

      40 Larsson HB, "Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors" 16 : 117-131, 1990

      41 Dujardin M, "Quantification of renal perfusion and function on a voxel-by-voxel basis: a feasibility study" 54 : 841-849, 2005

      42 Kim SG, "Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping" 34 : 293-301, 1995

      43 Singh A, "Quantification of physiological and hemodynamic indices using T(1) dynamic contrast-enhanced MRI in intracranial mass lesions" 26 : 871-880, 2007

      44 Calamante F, "Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: assumptions, limitations, and potential implications for clinical use" 33 : 1146-1151, 2002

      45 Zhu XP, "Quantification of endothelial permeability, leakage space, and blood volume in brain tumors using combined T1 and T2* contrast-enhanced dynamic MR imaging" 11 : 575-585, 2000

      46 Sourbron S, "Quantification of cerebral blood flow, cerebral blood volume, and blood-brain-barrier leakage with DCE-MRI" 62 : 205-217, 2009

      47 Calamante F, "Quantification of bolus-tracking MRI: improved characterization of the tissue residue function using Tikhonov regularization" 50 : 1237-1247, 2003

      48 Edelman RR, "Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency" 192 : 513-520, 1994

      49 Luh WM, "QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling" 41 : 1246-1254, 1999

      50 Choi YJ, "Pseudoprogression in patients with glioblastoma: added value of arterial spin labeling to dynamic susceptibility contrast perfusion MR imaging" 54 : 448-454, 2013

      51 Dixon WT, "Projection angiograms of blood labeled by adiabatic fast passage" 3 : 454-462, 1986

      52 Weisskoff RM, "Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time?" 29 : 553-558, 1993

      53 Bleeker EJ, "Phase-based arterial input function measurements for dynamic susceptibility contrast MRI" 64 : 358-368, 2010

      54 Helle M, "Perfusion territory imaging of intracranial branching arteries - optimization of continuous artery-selective spin labeling (CASSL)" 24 : 404-412, 2011

      55 Rosen BR, "Perfusion imaging with NMR contrast agents" 14 : 249-265, 1990

      56 Pandharipande PV, "Perfusion imaging of the liver: current challenges and future goals" 234 : 661-673, 2005

      57 Detre JA, "Perfusion imaging" 23 : 37-45, 1992

      58 Speck O, "Perfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques" 12 : 381-387, 2000

      59 Martel AL, "Perfusion MRI of infarcted and noninfarcted brain tissue in stroke: a comparison of conventional hemodynamic imaging and factor analysis of dynamic studies" 36 : 378-385, 2001

      60 Johnson NA, "Pattern of cerebral hypoperfusion in Alzheimer disease and mild cognitive impairment measured with arterial spin-labeling MR imaging: initial experience" 234 : 851-859, 2005

      61 Chappell MA, "Partial volume correction of multiple inversion time arterial spin labeling MRI data" 65 : 1173-1183, 2011

      62 Bleeker EJ, "Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI" 29 : 840-852, 2009

      63 Meier P, "On the theory of the indicator-dilution method for measurement of blood flow and volume" 6 : 731-744, 1954

      64 Kiselev VG, "On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI" 46 : 1113-1122, 2001

      65 Gall P, "On the design of filters for Fourier and oSVD-based deconvolution in bolus tracking perfusion MRI" 23 : 187-195, 2010

      66 Zanderigo F, "Nonlinear stochastic regularization to characterize tissue residue function in bolus-tracking MRI: assessment and comparison with SVD, block-circulant SVD, and Tikhonov" 56 : 1287-1297, 2009

      67 Calamante F, "Nonlinear DeltaR*2 effects in perfusion quantification using bolus-tracking MRI" 61 : 486-492, 2009

      68 Brookes MJ, "Noninvasive measurement of arterial cerebral blood volume using Look-Locker EPI and arterial spin labeling" 58 : 41-54, 2007

      69 Detre JA, "Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease" 50 : 633-641, 1998

      70 Ye FQ, "Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST)" 44 : 92-100, 2000

      71 Wong EC, "New developments in arterial spin labeling pulse sequences" 26 : 887-891, 2013

      72 Bleeker EJ, "New criterion to aid manual and automatic selection of the arterial input function in dynamic susceptibility contrast MRI" 65 : 448-456, 2011

      73 Erlemann R, "Musculoskeletal neoplasms: static and dynamic Gd-DTPA--enhanced MR imaging" 171 : 767-773, 1989

      74 Zaharchuk G, "Multislice perfusion and perfusion territory imaging in humans with separate label and image coils" 41 : 1093-1098, 1999

      75 Alsop DC, "Multisection cerebral blood flow MR imaging with continuous arterial spin labeling" 208 : 410-416, 1998

      76 Dixon WT, "Multiple inversion recovery reduces static tissue signal in angiograms" 18 : 257-268, 1991

      77 Tofts PS, "Modeling tracer kinetics in dynamic Gd-DTPA MR imaging" 7 : 91-101, 1997

      78 Francis ST, "Modeling and optimization of Look-Locker spin labeling for measuring perfusion and transit time changes in activation studies taking into account arterial blood volume" 59 : 316-325, 2008

      79 Mehndiratta A, "Modeling and correction of bolus dispersion effects in dynamic susceptibility contrast MRI" 2014

      80 Petersen ET, "Model-free arterial spin labeling quantification approach for perfusion MRI" 55 : 219-232, 2006

      81 Willats L, "Minimising the effects of bolus dispersion in bolus-tracking MRI" 21 : 1126-1137, 2008

      82 Weisskoff RM, "Microscopic susceptibility variation and transverse relaxation: theory and experiment" 31 : 601-610, 1994

      83 Brix G, "Microcirculation and microvasculature in breast tumors: pharmacokinetic analysis of dynamic MR image series" 52 : 420-429, 2004

      84 van Osch MJ, "Measuring the arterial input function with gradient echo sequences" 49 : 1067-1076, 2003

      85 Calamante F, "Measuring cerebral blood flow using magnetic resonance imaging techniques" 19 : 701-735, 1999

      86 Tofts PS, "Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts" 17 : 357-367, 1991

      87 Vonken EJ, "Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI" 10 : 109-117, 1999

      88 Larsson HB, "Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla" 62 : 1270-1281, 2009

      89 Hartkamp NS, "Mapping of cerebral perfusion territories using territorial arterial spin labeling: techniques and clinical application" 26 : 901-912, 2013

      90 Williams DS, "Magnetic resonance imaging of perfusion using spin inversion of arterial water" 89 : 212-216, 1992

      91 Kwong KK, "MR perfusion studies with T1-weighted echo planar imaging" 34 : 878-887, 1995

      92 Boxerman JL, "MR contrast due to intravascular magnetic susceptibility perturbations" 34 : 555-566, 1995

      93 Grüner R, "Iterative blind deconvolution in magnetic resonance brain perfusion imaging" 55 : 805-815, 2006

      94 Thompson HK Jr, "Indicator transit time considered as a gamma variate" 14 : 502-515, 1964

      95 Parker GJ, "Improving image quality and T(1) measurements using saturation recovery turboFLASH with an approximate K-space normalisation filter" 18 : 157-167, 2000

      96 Jahng GH, "Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions" 49 : 307-314, 2003

      97 Liang X, "Improved partial volume correction for single inversion time arterial spin labeling data" 69 : 531-537, 2013

      98 Willats L, "Improved deconvolution of perfusion MRI data in the presence of bolus delay and dispersion" 56 : 146-156, 2006

      99 Jahng GH, "Improved arterial spin labeling method: applications for measurements of cerebral blood flow in human brain at high magnetic field MRI" 34 : 4519-4525, 2007

      100 Wong EC, "Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling" 10 : 237-249, 1997

      101 Du AT, "Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI" 67 : 1215-1220, 2006

      102 Ostergaard L, "High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis" 36 : 715-725, 1996

      103 Kao YH, "Hemodynamic segmentation of MR brain perfusion images using independent component analysis, thresholding, and Bayesian estimation" 49 : 885-894, 2003

      104 Liang X, "Graph analysis of resting-state ASL perfusion MRI data: nonlinear correlations among CBF and network metrics" 87 : 265-275, 2014

      105 Stanisz GJ, "Gd-DTPA relaxivity depends on macromolecular content" 44 : 665-667, 2000

      106 Choyke PL, "Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging" 17 : 509-520, 2003

      107 Ordidge RJ, "Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy" 36 : 562-566, 1996

      108 Li KL, "Four-phase single-capillary stepwise model for kinetics in arterial spin labeling MRI" 53 : 511-518, 2005

      109 Hendrikse J, "Flow territory mapping of the cerebral arteries with regional perfusion MRI" 35 : 882-887, 2004

      110 Silva AC, "Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion" 38 : 232-237, 1997

      111 Calamante F, "Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics" 19 (19): 341-353, 2003

      112 Tofts PS, "Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols" 10 : 223-232, 1999

      113 Günther M, "Efficient visualization of vascular territories in the human brain by cycled arterial spin labeling MRI" 56 : 671-675, 2006

      114 Garcia DM, "Efficiency of inversion pulses for background suppressed arterial spin labeling" 54 : 366-372, 2005

      115 Covarrubias DJ, "Dynamic magnetic resonance perfusion imaging of brain tumors" 9 : 528-537, 2004

      116 Larsson HB, "Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T1-weighted MRI at 3T" 27 : 754-762, 2008

      117 Zimine I, "Dual vessel arterial spin labeling scheme for regional perfusion imaging" 56 : 1140-1144, 2006

      118 Landis CS, "Determination of the MRI contrast agent concentration time course in vivo following bolus injection: effect of equilibrium transcytolemmal water exchange" 44 : 563-574, 2000

      119 Calamante F, "Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition" 44 : 466-473, 2000

      120 Calamante F, "Defining a local arterial input function for perfusion MRI using independent component analysis" 52 : 789-797, 2004

      121 Moody AR, "Contrast-reduced imaging of tissue concentration and arterial level (CRITICAL) for assessment of cerebral hemodynamics in acute stroke by magnetic resonance" 35 : 401-411, 2000

      122 Rosen BR, "Contrast agents and cerebral hemodynamics" 19 : 285-292, 1991

      123 Calamante F, "Contrast agent concentration measurements affecting quantification of bolus-tracking perfusion MRI" 58 : 544-553, 2007

      124 Dai W, "Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields" 60 : 1488-1497, 2008

      125 Fernández-Seara MA, "Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T" 54 : 1241-1247, 2005

      126 Starmer CF, "Computer computations of cardiac output using the gamma function" 28 : 219-220, 1970

      127 Provenzale JM, "Comparison of permeability in high-grade and low-grade brain tumors using dynamic susceptibility contrast MR imaging" 178 : 711-716, 2002

      128 Law M, "Comparison of cerebral blood volume and vascular permeability from dynamic susceptibility contrast-enhanced perfusion MR imaging with glioma grade" 25 : 746-755, 2004

      129 Chen Y, "Comparison of arterial transit times estimated using arterial spin labeling" 25 : 135-144, 2012

      130 Zaharchuk G, "Combined arterial spin label and dynamic susceptibility contrast measurement of cerebral blood flow" 63 : 1548-1556, 2010

      131 Bokkers RP, "Cerebrovascular reactivity within perfusion territories in patients with an internal carotid artery occlusion" 82 : 1011-1016, 2011

      132 Gonzalez-At JB, "Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling" 43 : 739-746, 2000

      133 Buckley DL, "Cellular-interstitial water exchange and its effect on the determination of contrast agent concentration in vivo: dynamic contrast-enhanced MRI of human internal obturator muscle" 60 : 1011-1019, 2008

      134 Simonsen CZ, "CBF and CBV measurements by USPIO bolus tracking: reproducibility and comparison with Gd-based values" 9 : 342-347, 1999

      135 Calamante F, "Bolus dispersion issues related to the quantification of perfusion MRI data" 22 : 718-722, 2005

      136 Calamante F, "Bolus delay and dispersion in perfusion MRI: implications for tissue predictor models in stroke" 55 : 1180-1185, 2006

      137 Kershaw LE, "Benign prostatic hyperplasia: evaluation of T1, T2, and microvascular characteristics with T1-weighted dynamic contrast-enhanced MRI" 29 : 641-648, 2009

      138 Mouridsen K, "Bayesian estimation of cerebral perfusion using a physiological model of microvasculature" 33 : 570-579, 2006

      139 Warnking JM, "Bandwidth-modulated adiabatic RF pulses for uniform selective saturation and inversion" 52 : 1190-1199, 2004

      140 Lorenz C, "Automated perfusion-weighted MRI using localized arterial input functions" 24 : 1133-1139, 2006

      141 Wirestam R, "Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques" 43 : 691-700, 2000

      142 Materne R, "Assessment of hepatic perfusion parameters with dynamic MRI" 47 : 135-142, 2002

      143 Alsop DC, "Arterial spin labeling: its time is now" 25 : 75-77, 2012

      144 Feinberg DA, "Arterial spin labeling with simultaneous multi-slice echo planar imaging" 70 : 1500-1506, 2013

      145 Paiva FF, "Arterial spin labeling of cerebral perfusion territories using a separate labeling coil" 27 : 970-977, 2008

      146 Günther M, "Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR)" 46 : 974-984, 2001

      147 Calamante F, "Arterial input function in perfusion MRI: a comprehensive review" 74 : 1-32, 2013

      148 Leigh R, "Arrival time correction for dynamic susceptibility contrast MR permeability imaging in stroke patients" 7 : e52656-, 2012

      149 Jerosch-Herold M, "Analysis of myocardial perfusion MRI" 19 : 758-770, 2004

      150 Wong EC, "An introduction to ASL labeling techniques" 40 : 1-10, 2014

      151 Wu Y, "An independent component analysis approach for minimizing effects of recirculation in dynamic susceptibility contrast magnetic resonance imaging" 27 : 632-645, 2007

      152 Li KL, "An improved coverage and spatial resolution--using dual injection dynamic contrast-enhanced (ICE-DICE) MRI: a novel dynamic contrast-enhanced technique for cerebral tumors" 68 : 452-462, 2012

      153 St Lawrence KS, "An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: II. Experimental validation" 18 : 1378-1385, 1998

      154 Haller S, "Acute caffeine administration impact on working memory-related brain activation and functional connectivity in the elderly: a BOLD and perfusion MRI study" 250 : 364-371, 2013

      155 Benner T, "Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise" 15 : 307-317, 1997

      156 Hayasaka S, "A non-parametric approach for co-analysis of multi-modal brain imaging data: application to Alzheimer’s disease" 30 : 768-779, 2006

      157 Liang X, "A k-space sharing 3D GRASE pseudocontinuous ASL method for whole-brain resting-state functional connectivity" 22 : 37-43, 2012

      158 Buxton RB, "A general kinetic model for quantitative perfusion imaging with arterial spin labeling" 40 : 383-396, 1998

      159 Chappell MA, "A general framework for the analysis of vessel encoded arterial spin labeling for vascular territory mapping" 64 : 1529-1539, 2010

      160 Bjørnerud A, "A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI" 30 : 1066-1078, 2010

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.61 0.46 1.15
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.93 0.84 0.494 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼