<P> This study was designed to evaluate the efficacy of dynamic parameters, such as correlation dimension D<SUB>2</SUB>, by comparing spectral electroencephalographic (EEG) parameters. These parameters are used to estimate the depth ...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A105379527
1999
-
518
SCIE,SCOPUS,KCI등재
학술저널
491-499(9쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P> This study was designed to evaluate the efficacy of dynamic parameters, such as correlation dimension D<SUB>2</SUB>, by comparing spectral electroencephalographic (EEG) parameters. These parameters are used to estimate the depth ...
<P> This study was designed to evaluate the efficacy of dynamic parameters, such as correlation dimension D<SUB>2</SUB>, by comparing spectral electroencephalographic (EEG) parameters. These parameters are used to estimate the depth of halothane anesthesia as defined by the presence of body movement in response to a tail clamp. Six rats were used and each of them was exposed to halothane sequentially at the concentrations of 0%, 0.5%, 1.0% and 1.5% for 30 min. A tail clamp was applied every five min and the movements were recorded at each concentration level. The spectral parameters and the dynamic parameters were derived from 20-sec and 10-sec segments, respectively, from the last 5-mins of EEG recording at each concentration level. Correlation coefficients between the parameters and the movements were calculated. Standardized values of three parameters, betaL power, median power frequency (MPF), and D<SUB>2</SUB> were derived by calculation based on the number of animals showing the movement in response to a tail clamp. The betaL power had the largest correlation coefficient to spontaneous movement and to the response to a tail clamp than any other band parameter. MPF had a better correlation with the movement than 90% spectral edge frequency. Among the dynamic parameters, D<SUB>2</SUB> on the parietal cortex had a better correlation with the movement. The level of deviation and variation of standardized D<SUB>2</SUB>, MPF, and betaL were significant (p<0.01). The order of deviation and variation was; betaL power>MPF>D<SUB>2</SUB>. The correlation dimension serves as a better index for the depth of halothane anesthesia defined in forms of a response to external stimulation.
A Novel Mechanism of Bitter Taste Transduction
Physiological and Pharmacological Characterization of Glutamate and GABA Receptors in the Retina