RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Objective Monitoring of Brace Wearing Time in Adolescents with Scheuermann’s Kyphosis

      한글로보기

      https://www.riss.kr/link?id=A106477926

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Study Design: This was a prospective cohort study. Purpose: This study aimed to evaluate the potential differences between the objective and subjective bracing compliances of adolescents with Scheuermann’s kyphosis. Overview of Literature: Bracing i...

      Study Design: This was a prospective cohort study.
      Purpose: This study aimed to evaluate the potential differences between the objective and subjective bracing compliances of adolescents with Scheuermann’s kyphosis.
      Overview of Literature: Bracing is a well-documented intervention for managing adolescents with progressive thoracic Scheuermann’s kyphosis, and the brace should be worn 23 hours every day. Most research studies that have investigated the efficacy of bracing have assumed that the patients wore the braces as advised or that the bracing time was measured subjectively. This may be one of the reasons for the conflicting reports regarding the efficacy of bracing.
      Methods: Nineteen volunteers (11 girls and 7 boys, 12.89±1.77 years) who were prescribed Milwaukee braces for Scheuermann’s kyphosis were enrolled. Each brace was equipped with a miniature temperature logger to record the actual brace wearing time over a period of 3 weeks. The patients and their families were unaware of the mounted sensor. Each participants and/or parent was provided with a questionnaire to record the number of hours for which the brace was worn each day. In addition, the therapist asked each patient and/or his/her parent about the average number of hours that the brace was worn.
      Results: The compliance rates measured using the temperature logger (16.00±4.90 hours daily) were significantly lower than those reported in the questionnaires (19.52±6.04 hours daily, p<0.001) and the verbal responses (20.21±6.05 hours daily, p<0.001). Moreover, there was no correlation of age, sex, and body mass index with brace compliance.
      Conclusions: The braces were worn less often than reported by the patients and/or their parents. Therefore, objective compliance assessments of adolescents with Scheuermann’s kyphosis in a brace are recommended for future studies.

      더보기

      참고문헌 (Reference)

      1 Benish BM, "Validation of a miniature thermochron for monitoring thoracolumbosacral orthosis wear time" 37 : 309-315, 2012

      2 Noonan KJ, "Use of the Milwaukee brace for progressive idiopathic scoliosis" 78 : 557-567, 1996

      3 Fon GT, "Thoracic kyphosis : range in normal subjects" 134 : 979-983, 1980

      4 Nicholson GP, "The objective measurement of spinal orthosis use for the treatment of adolescent idiopathic scoliosis" 28 : 2243-2250, 2003

      5 Helfenstein A, "The objective determination of compliance in treatment of adolescent idiopathic scoliosis with spinal orthoses" 31 : 339-344, 2006

      6 Rahman T, "The association between brace compliance and outcome for patients with idiopathic scoliosis" 25 : 420-422, 2005

      7 Hart ES, "Scheuermann’s thoracic kyphosis in the adolescent patient" 29 : 365-371, 2010

      8 Montgomery SP, "Scheuermann’s kyphosis : long-term results of Milwaukee braces treatment" 6 : 5-8, 1981

      9 Hasler CC, "Objective compliance of adolescent girls with idiopathic scoliosis in a dynamic SpineCor brace" 4 : 211-218, 2010

      10 Brigham EM, "Motivations for compliance with bracing in adolescent idiopathic scoliosis" 5 : 46-51, 2017

      1 Benish BM, "Validation of a miniature thermochron for monitoring thoracolumbosacral orthosis wear time" 37 : 309-315, 2012

      2 Noonan KJ, "Use of the Milwaukee brace for progressive idiopathic scoliosis" 78 : 557-567, 1996

      3 Fon GT, "Thoracic kyphosis : range in normal subjects" 134 : 979-983, 1980

      4 Nicholson GP, "The objective measurement of spinal orthosis use for the treatment of adolescent idiopathic scoliosis" 28 : 2243-2250, 2003

      5 Helfenstein A, "The objective determination of compliance in treatment of adolescent idiopathic scoliosis with spinal orthoses" 31 : 339-344, 2006

      6 Rahman T, "The association between brace compliance and outcome for patients with idiopathic scoliosis" 25 : 420-422, 2005

      7 Hart ES, "Scheuermann’s thoracic kyphosis in the adolescent patient" 29 : 365-371, 2010

      8 Montgomery SP, "Scheuermann’s kyphosis : long-term results of Milwaukee braces treatment" 6 : 5-8, 1981

      9 Hasler CC, "Objective compliance of adolescent girls with idiopathic scoliosis in a dynamic SpineCor brace" 4 : 211-218, 2010

      10 Brigham EM, "Motivations for compliance with bracing in adolescent idiopathic scoliosis" 5 : 46-51, 2017

      11 Bezalel T, "Improvement of clinical and radiographical presentation of Scheuermann disease after Schroth therapy treatment" 19 : 232-237, 2015

      12 Climent JM, "Impact of the type of brace on the quality of life of adolescents with spine deformities" 24 : 1903-1908, 1999

      13 Brox JI, "Good brace compliance reduced curve progression and surgical rates in patients with idiopathic scoliosis" 21 : 1957-1963, 2012

      14 Rahman T, "Electronic monitoring of scoliosis brace wear compliance" 4 : 343-347, 2010

      15 Miller DJ, "Electronic monitoring improves brace-wearing compliance in patients with adolescent idiopathic scoliosis : a randomized clinical trial" 37 : 717-721, 2012

      16 Hans-Rudolf Weiss, "Development of CAD/CAM Based Brace Models for the Treatment of Patients with Scoliosis-Classification Based Approach versus Finite Element Modelling" 대한척추외과학회 9 (9): 661-667, 2015

      17 Lou E, "Correlation between quantity and quality of orthosis wear and treatment outcomes in adolescent idiopathic scoliosis" 28 : 49-54, 2004

      18 Takemitsu M, "Compliance monitoring of brace treatment for patients with idiopathic scoliosis" 29 : 2070-2074, 2004

      19 Korovessis P, "Comparative multifactorial analysis of the effects of idiopathic adolescent scoliosis and Scheuermann kyphosis on the self-perceived health status of adolescents treated with brace" 16 : 537-546, 2007

      20 Lindeman M, "Cognitive strategies and selfesteem as predictors of brace-wear noncompliance in patients with idiopathic scoliosis and kyphosis" 19 : 493-499, 1999

      21 Weiss HR, "Brace treatment for patients with Scheuermann’s disease : a review of the literature and first experiences with a new brace design" 4 : 22-, 2009

      22 Lou E, "An objective measurement of brace usage for the treatment of adolescent idiopathic scoliosis" 33 : 290-294, 2011

      23 Gurnham RB, "Adolescent compliance with spinal brace wear" 2 : 13-17, 1983

      24 Morton A, "Accuracy in the prediction and estimation of adherence to bracewear before and during treatment of adolescent idiopathic scoliosis" 28 : 336-341, 2008

      25 Katz DE, "AAOS atlas of orthoses and assistive devices" Elsevier Health Sciences 125-139, 2008

      26 Havey R, "A reliable and accurate method for measuring orthosis wearing time" 27 : 211-214, 2002

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 선정 (해외등재 학술지 평가) KCI등재
      2020-12-01 평가 등재 탈락 (해외등재 학술지 평가)
      2013-10-01 평가 등재학술지 선정 (기타) KCI등재
      2011-01-01 평가 SCOPUS 등재 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0 0 0
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0 0 0 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼