      농연 및 화염 손상 환경에서 소방복의 가시성 평가 = Evaluation of Firefighter Turnout Gear Visibility in Smoke Obscuration and Flame Damage

      한글로보기

      https://www.riss.kr/link?id=A106287739

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study aimed at evaluating the visibility of new and damaged firefighter turnout gear by smoke and light intensities. Eight firefighters evaluated the visibility of turnout gear within the range of 0 (not visible) to 100 (very visible) points. Additional experiments using LED bands and flashlights were performed. Under the day condition, the visibility scores of new and damaged FPC were 2.1 and 1.8 points respectively, under the smoke condition, while the visibility scores were 100.0 and 66.3 points under the no-smoke condition. There were significant differences in the visibility scores between smoke and no-smoke conditions, and between new and damaged FPC under the no-smoke condition. Under the night condition, the visibility scores were all 0 points under the smoke condition, while the visibility scores were 10.1 points (new) and 5.4 points (damaged), under the no-smoke condition. Meanwhile, these visibility scores under the night-no smoke condition were improved up to 47.8 points (new) and 45.3 points (damaged) with the LED bands, and 45.0 points (new) and 35.6 points (damaged) with flashlights.
      번역하기

      This study aimed at evaluating the visibility of new and damaged firefighter turnout gear by smoke and light intensities. Eight firefighters evaluated the visibility of turnout gear within the range of 0 (not visible) to 100 (very visible) points. Add...

      This study aimed at evaluating the visibility of new and damaged firefighter turnout gear by smoke and light intensities. Eight firefighters evaluated the visibility of turnout gear within the range of 0 (not visible) to 100 (very visible) points. Additional experiments using LED bands and flashlights were performed. Under the day condition, the visibility scores of new and damaged FPC were 2.1 and 1.8 points respectively, under the smoke condition, while the visibility scores were 100.0 and 66.3 points under the no-smoke condition. There were significant differences in the visibility scores between smoke and no-smoke conditions, and between new and damaged FPC under the no-smoke condition. Under the night condition, the visibility scores were all 0 points under the smoke condition, while the visibility scores were 10.1 points (new) and 5.4 points (damaged), under the no-smoke condition. Meanwhile, these visibility scores under the night-no smoke condition were improved up to 47.8 points (new) and 45.3 points (damaged) with the LED bands, and 45.0 points (new) and 35.6 points (damaged) with flashlights.

      더보기

      참고문헌 (Reference)

      1 이근원, "콘칼로리미터를 이용한 플라스틱 단열재의 화재특성" 한국화재소방학회 17 (17): 76-83, 2003

      2 정동석, "재귀반사 섬유의 개발 (Ⅰ) - Slit Yarn의 제조와 경사에 Slit Yarn사용에 의한 직물제조 -" 한국염색가공학회 29 (29): 139-147, 2017

      3 정문기, "용매저항성 폴리벤즈이미다졸 분리막의 제조 및 특성평가" 한국공업화학회 28 (28): 420-426, 2017

      4 National Fire Agency, "소방장비 관리 규칙(총리령 제1105호)"

      5 Korea Fire Institute, "소방용 특수방화복의 인증규칙"

      6 National Fire Agency, "소방시설 등의 성능위주설계 방법 및 기준 (고시 제 2017-1호)"

      7 Ministry of the Interior and Safety, "소방공무원임용령 시행규칙"

      8 "산업및 교통안전용 재귀반사 시트, KS T 3507"

      9 소범식, "고효율 재귀 반사체 형상에 관한 연구" 한국정밀공학회 19 (19): 2002

      10 Jenssen, G. D., "study of the visibility and effectiveness of fluorescent retroreflective traffic control signing in work zone applications (No. VTI konferens 9A part 6)" Swedish national road and transport research institute 1998

      1 이근원, "콘칼로리미터를 이용한 플라스틱 단열재의 화재특성" 한국화재소방학회 17 (17): 76-83, 2003

      2 정동석, "재귀반사 섬유의 개발 (Ⅰ) - Slit Yarn의 제조와 경사에 Slit Yarn사용에 의한 직물제조 -" 한국염색가공학회 29 (29): 139-147, 2017

      3 정문기, "용매저항성 폴리벤즈이미다졸 분리막의 제조 및 특성평가" 한국공업화학회 28 (28): 420-426, 2017

      4 National Fire Agency, "소방장비 관리 규칙(총리령 제1105호)"

      5 Korea Fire Institute, "소방용 특수방화복의 인증규칙"

      6 National Fire Agency, "소방시설 등의 성능위주설계 방법 및 기준 (고시 제 2017-1호)"

      7 Ministry of the Interior and Safety, "소방공무원임용령 시행규칙"

      8 "산업및 교통안전용 재귀반사 시트, KS T 3507"

      9 소범식, "고효율 재귀 반사체 형상에 관한 연구" 한국정밀공학회 19 (19): 2002

      10 Jenssen, G. D., "study of the visibility and effectiveness of fluorescent retroreflective traffic control signing in work zone applications (No. VTI konferens 9A part 6)" Swedish national road and transport research institute 1998

      11 Zwahlen, H., "Visual detection and recognition of fluorescent color targets versus nonfluorescent color targets as a function of peripheral viewing angle and target size" 1605 : 28-40, 1997

      12 Jin, T, "Visibility through fire smoke(I)" 19 (19): 1-8, 1970

      13 Ko, M. S., "The study on the improving visibility by LED luminaires at safety zone" 126-130, 2014

      14 E. A. Manyukov, "Study of Dyeing of Thermostable Para/Meta-Aramid Fibre" Springer Science and Business Media LLC 37 (37): 54-58, 2005

      15 Jin, T., "Studies on human behavior and tenability in fire smoke" 5 : 3-21, 1997

      16 Jin, T., "Studies on decrease of thinking powers and of memory in fire Smoke" 32 (32): 43-47, 1982

      17 Jin, T., "Studies of emotional instability in smoke from fires" 12 (12): 130-142, 1981

      18 "Standard practice for measuring photometric characteristics of retroreflectors, ASTM E809:08"

      19 "Standard on selection, care, and maintenance of protective ensembles for structural fire fighting and proximity firefighting, NFPA 1851"

      20 "Standard on protective ensembles for structural firefighting and proximity firefighting, NFPA 1971"

      21 No, J. S., "Smoke movement by a fire in an enclosure" 10 (10): 10-18, 1996

      22 Hanson, D., "Significant visual properties of some fluorescent pigments" Highway Research Board, National Research Council 1963

      23 Yamada, T., "SFPE Handbook of Fire Protection Engineering" Springer 2181-2206, 2016

      24 "Protective clothing for firefighters -Performance requirements for protective clothing for firefighting, BS EN 469"

      25 "Protective clothing for firefighters -Laboratory test methods and performance requirements, ISO 11613"

      26 "Protective clothing against heat and flame-Determination of heat transmission on exposure to flame, ISO 9151"

      27 "Protective clothing against heat and flame - Part 1: Test method for complete garments -Measurement of transferred energy using an instrumented manikin, ISO 13506-1"

      28 "Protective clothing - Protection against heat and fire - Method of test: Evaluation of materials and material assemblies when exposed to a source of radiant heat, ISO 6942"

      29 "PPE for firefighters - Test methods and requirements for PPE used by firefighters who are at risk of exposure to high levels of heat and/or flame while fighting fires occurring in structures - Part 3:Clothing, ISO 11999-3"

      30 "High visibility clothing - Test methods and requirements, ISO 20471"

      31 Deena Cotterill, "Firefighter Turnout Gear Durability Study—Evaluation of Visibility Trim" Springer Science and Business Media LLC 47 (47): 601-613, 2011

      32 Han, I. S., "Extreme textiles; Specification and application of aramid fiber" 10 (10): 339-349, 2006

      33 Chae, S. U., "Development of real scale test methods of building (interior and exterior)materials and safety design guidelines" 169-170, 2015

      34 Kim, W. H., "A Smoke Hazard Test of Interior Finish Materials" Korean Institute of Fire Science & Engineering 75-79, 2000

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-09-23 학술지등록 한글명 : 한국생활환경학회지
      외국어명 : The Korean Society of Living Environmental System
      KCI등재후보
      2004-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.29 0.29 0.28
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.31 0.3 0.376 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼