      The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

      한글로보기

      https://www.riss.kr/link?id=A106663900

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on ...

      Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults.
      Design: Descriptive laboratory study.
      Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder.
      Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra- rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05).
      This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement.
      Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

      더보기

      참고문헌 (Reference)

      1 Shin SH, "Within-day reliability of shoulder range of motion measurement with a smartphone" 17 : 298-304, 2012

      2 Audette I, "Validity and between-day reliability of the cervical range of motion (CROM)device" 40 : 318-323, 2010

      3 Goshtigian GR, "Using the selective functional movement assessment and regional interdependence theory to guide treatment of an athlete with back pain: a case report" 11 : 575-595, 2016

      4 Kebaetse M, "Thoracic position effect on shoulder range of motion, strength, and three-dimensional scapular kinematics" 80 : 945-950, 1999

      5 Theodoridis D, "The effect of shoulder movements on thoracic spine 3D motion" 17 : 418-421, 2002

      6 Johnson KD, "Reliability of thoracic spine rotation range-of-motion measurements in healthy adults" 47 : 52-60, 2012

      7 Nitschke JE, "Reliability of the American Medical Association guides' model for measuring spinal range of motion. Its implication for wholeperson impairment rating" 24 : 262-268, 1999

      8 Charlton PC, "Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion" 18 : 262-267, 2015

      9 Cook EG, "Physical Therapy Course Manual Edited" Functional Movement 2004

      10 Krzyzanowicz R, "Patient outcomes utilizing the selective functional movement assessment and mulligan mobilizations with movement on recreational dancers with sacroiliac joint pain : a case series" 20 : 31-37, 2015

      1 Shin SH, "Within-day reliability of shoulder range of motion measurement with a smartphone" 17 : 298-304, 2012

      2 Audette I, "Validity and between-day reliability of the cervical range of motion (CROM)device" 40 : 318-323, 2010

      3 Goshtigian GR, "Using the selective functional movement assessment and regional interdependence theory to guide treatment of an athlete with back pain: a case report" 11 : 575-595, 2016

      4 Kebaetse M, "Thoracic position effect on shoulder range of motion, strength, and three-dimensional scapular kinematics" 80 : 945-950, 1999

      5 Theodoridis D, "The effect of shoulder movements on thoracic spine 3D motion" 17 : 418-421, 2002

      6 Johnson KD, "Reliability of thoracic spine rotation range-of-motion measurements in healthy adults" 47 : 52-60, 2012

      7 Nitschke JE, "Reliability of the American Medical Association guides' model for measuring spinal range of motion. Its implication for wholeperson impairment rating" 24 : 262-268, 1999

      8 Charlton PC, "Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion" 18 : 262-267, 2015

      9 Cook EG, "Physical Therapy Course Manual Edited" Functional Movement 2004

      10 Krzyzanowicz R, "Patient outcomes utilizing the selective functional movement assessment and mulligan mobilizations with movement on recreational dancers with sacroiliac joint pain : a case series" 20 : 31-37, 2015

      11 Milani P, "Mobile smartphone applications for body position measurement in rehabilitation: a review of goniometric tools" 6 : 1038-1043, 2014

      12 Chen J, "Meta-analysis of normative cervical motion" 24 : 1571-1578, 1999

      13 Fujimori T, "Kinematics of the thoracic spine in trunk rotation: in vivo 3-dimensional analysis" 37 : E1318-E1328, 2012

      14 Glaws KR, "Intra- and inter-rater reliability of the selective functional movement assessment (SFMA)" 9 : 195-207, 2014

      15 Edmondston SJ, "Influence of posture on the range of axial rotation and coupled lateral flexion of the thoracic spine" 30 : 193-199, 2007

      16 Gajdosik RL, "Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity" 67 : 1867-1872, 1987

      17 Fernández-de-las-Peñas C, "Changes in neck pain and active range of motion after a single thoracic spine manipulation in subjects presenting with mechanical neck pain : a case series" 30 : 312-320, 2007

      18 Pearcy MJ, "Axial rotation and lateral bending in the normal lumbar spine measured by three-dimensional radiography" 9 : 582-587, 1984

      19 White AA 3rd, "Analysis of the mechanics of the thoracic spine in man. An experimental study of autopsy specimens" 127 (127): 1-105, 1969

      20 Willems JM, "An in vivo study of the primary and coupled rotations of the thoracic spine" 11 : 311-316, 1996

      21 Gregersen GG, "An in vivo study of the axial rotation of the human thoracolumbar spine" 49 : 247-262, 1967

      22 Dvorak J, "Age and gender related normal motion of the cervical spine" 17 (17): S393-S398, 1992

      23 Nash CL Jr, "A study of vertebral rotation" 51 : 223-229, 1969

      24 Rome K, "A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion" 17 : 28-32, 1996

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2015-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0 0 0
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0 0 0 0.15
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼