RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique

      한글로보기

      https://www.riss.kr/link?id=A107745370

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P><P><B>Background</B></P><P>The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with ...

      <P><B>Abstract</B></P><P><B>Background</B></P><P>The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT).</P><P><B>Patients and methods</B></P><P>To investigate how arc arrangements affect dosimetric and biological metrics, SBRT-VMAT plans for eighteen patients were generated with arrangements of single-full arc (1FA), single-partial arc (1PA), double-full arc (2FA), and double-partial arc (2PA). All plans were calculated by the Acuros XB calculation algorithm. Dosimetric and radiobiological metrics for target volumes and organs at risk (OARs) were evaluated from dosevolume histograms.</P><P><B>Results</B></P><P>All plans were highly conformal (CI<1.05, CN=0.91) and homogeneous (HI=0.09-0.12) for target volumes. For OARs, there was no difference in the bladder dose, while there was a significant difference in the rectum and both femoral head doses. Plans using 1PA and 2PA showed a strong reduction to the mean rectum dose compared to plans using 1FA and 2FA. Contrastively, the D<SUB>2%</SUB> and mean dose in both femoral heads were always lower in plans using 1FA and 2FA. The average tumor control probability and normal tissue complication probability were comparable in plans using all arc arrangements.</P><P><B>Conclusions</B></P><P>The use of 1PA had a more effective delivery time and produced equivalent target coverage with better rectal sparing, although all plans using four arc arrangements showed generally similar for dosimetric and biological metrics. However, the D<SUB>2%</SUB> and mean dose in femoral heads increased slightly and remained within the tolerance. Therefore, this study suggests that the use of 1PA is an attractive choice for delivering prostate SBRT-VMAT.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼