      Evaluation of the resection effi ciency and safety of an enhanced power plasma generator using cadaveric intervertebral discs

      한글로보기

      https://www.riss.kr/link?id=A108752165

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Plasma energy has been used to provide minimally invasive interventional treatment for spinal problems. However, this procedure has been used for limited indications mainly because of its small resection range. To overcome this problem, we designed th...

      Plasma energy has been used to provide minimally invasive interventional treatment for spinal problems. However, this procedure has been used for limited indications mainly because of its small resection range. To overcome this problem, we designed the enhanced power plasma device. This device seeks to maximize the resection area by modifying the electrode arrangement and enhancing the maximum electric power. The purpose of this study is to assess the efficiency and safety of this newly designed plasma generator, a device for percutaneous disc decompression. We performed an intradiscal procedure on 7 fresh human cadaver lumbar spine specimens using the enhanced power plasma under C-arm fluoroscopic guidance at various voltages. As a result, the volume of the removed area was proportional to the applied magnitude of the electric power level. In particular, under the high-power level condition after 500 s treatment, nearly the entire nucleus pulposus was eliminated. The generated plasma density also tends to grow along with the given electric power. The highest level of temperature rise did not exceed the level that would lead to degeneration in the collagen tissue of the intervertebral disc. Histopathologic examination also demonstrated that there was no thermal damage to the surrounding neural tissues. In conclusion, we speculate that the concepts of this newly designed enhanced plasma generator could be applied to remove huge disc materials without thermal or structural damage to the adjacent target tissues in future spine clinics.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼