RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS SCIE

      Noncompliance screw supported maxillary molar distalization in a parallel manner = 미니스크류를 이용한 상악구치부 후방이동장치 효과

      한글로보기

      https://www.riss.kr/link?id=A82425577

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: Intraoral noncompliance upper molar distalization techniques have gained in popularity and have subsequently found to be successful in ClassⅡ correction. The aim of the present study was to introduce a screw supported intraoral distalizat...

      Objective: Intraoral noncompliance upper molar distalization techniques have gained in popularity and have subsequently found to be successful in ClassⅡ correction. The aim of the present study was to introduce a screw supported intraoral distalization appliance and investigate its efficiency. Methods: Twenty-one subjects (11 females, 10 males; average age of 14.9 years) with Angle ClassⅡ malocclusion participated in this study. Two screws were inserted behind the incisive foramen and immediately loaded to distalize the upper first molars. An intraoral screw supported distalization appliance was used to distalize the upper molars in order to achieve a ClassⅠ molar relationship. Skeletal and dental changes were evaluated using cephalometric and three-dimensional (3D) model analysis. Results: Upper molars were distalized 3.95 mm on average and a ClassⅠ molar relationship was achieved without any anchorage loss. The upper molars were tipped only and the upper right and left molars were rotated only 1.49˚ and the upper right and left molars were rotated only 0.54˚ and 0.74˚ respectively which were statistically non-significant (p > 0.05). Conclusions: The newly designed screw supported noncompliance distalization appliance was found to be an effective device for achieving bodily molar distalization without any anchorage loss.

      더보기

      국문 초록 (Abstract)

      상악 구치의 후방이동을 위한 구강 내 장치 중 환자의 협조를 필요로 하지 않는 방법은 제Ⅱ급 부정교합의 개선에 성공적으로 널리 사용되고 있다. 본 연구는 스크류에 의해 지지되는 구강 ...

      상악 구치의 후방이동을 위한 구강 내 장치 중 환자의 협조를 필요로 하지 않는 방법은 제Ⅱ급 부정교합의 개선에 성공적으로 널리 사용되고 있다. 본 연구는 스크류에 의해 지지되는 구강 내 후방이동 장치를 소개하고 그 효율성을 조사하고자 하였다. Angle ClassⅡ 부정교합으로 진단된 21명의 환자(여자 11명, 남자 10명; 평균 연령 14.9세)를 대상으로 하였다. 2개의 스크류를 incisive foramen 후방에 식립하고, 식립한 즉시 힘을 주어 상악 제1대구치의 후방이동에 사용하였다. 상악 구치를 후방이동시켜 제Ⅰ급 구치관계를 얻기 위해 스크류에 의해 지지되는 구강 내 후방이동 장치를 사용하였다. 치료 전후 측모두부 방사선 사진과 3차원 모델 분석을 통해 골격 및 치아의 변화를 평가하였다. 연구결과 상악 구치는 평균 3.95 mm 후방이동하였고, 추가적인 고정원 소실 없이 제Ⅰ급 구치관계를 확립하였다. 상악 대구치는 1.49˚후방경사 되었고, 회전된 정도는 좌우 각각 0.54˚, 0.74˚ 으로 통계적으로 유의성 있는 변화를 보이지 않았다 (p > 0.05). 새롭게 고안된 장치는 스크류에 의해 지지되어 환자의 협조도를 요하지 않으며 특별한 고정원 소실 없이 구치의 치체이동을 통한 후방이동을 얻는데 효과적인 것으로 판단된다.

      더보기

      참고문헌 (Reference)

      1 Linder-Aronson S, "Titanium implant anchorage in orthodontic treatment: an experimental investigation in monkeys" 12 : 414-9, 1990

      2 Gianelly AA, "The use of magnets to move molars distally" 96 : 161-7, 1989

      3 Doruk C, "The role of the headgear timer in extraoral co-operation" 26 : 289-91, 2004

      4 Ağar U, "The role of psycho-social factors in headgear compliance" 27 : 263-7, 2005

      5 Hilgers JJ, "The pendulum appliance for Class II non-compliance therapy" 26 : 706-14, 1992

      6 Smith DI, "The eruption of third molars following extraction of second molars" 8 : 292-4, 1958

      7 Carano A, "The distal jet for upper molar distalization" 30 : 374-80, 1996

      8 Dahlberg G, "Statistical methods for medical and biological students" Allen and Unwin, Ltd 9-232, 1948

      9 Roberts WE, "Rigid endosseous implants for orthodontic and orthopedic anchorage" 59 : 247-56, 1989

      10 Bondemark L, "Repelling magnets versus superelastic nickel-titanium coils in the simultaneous distal movement of maxillary first and second molars" 64 : 189-98, 1994

      1 Linder-Aronson S, "Titanium implant anchorage in orthodontic treatment: an experimental investigation in monkeys" 12 : 414-9, 1990

      2 Gianelly AA, "The use of magnets to move molars distally" 96 : 161-7, 1989

      3 Doruk C, "The role of the headgear timer in extraoral co-operation" 26 : 289-91, 2004

      4 Ağar U, "The role of psycho-social factors in headgear compliance" 27 : 263-7, 2005

      5 Hilgers JJ, "The pendulum appliance for Class II non-compliance therapy" 26 : 706-14, 1992

      6 Smith DI, "The eruption of third molars following extraction of second molars" 8 : 292-4, 1958

      7 Carano A, "The distal jet for upper molar distalization" 30 : 374-80, 1996

      8 Dahlberg G, "Statistical methods for medical and biological students" Allen and Unwin, Ltd 9-232, 1948

      9 Roberts WE, "Rigid endosseous implants for orthodontic and orthopedic anchorage" 59 : 247-56, 1989

      10 Bondemark L, "Repelling magnets versus superelastic nickel-titanium coils in the simultaneous distal movement of maxillary first and second molars" 64 : 189-98, 1994

      11 Jones RD, "Rapid Class II molar correction with an open coil jig" 26 : 661-4, 1992

      12 Ngantung V, "Posttreatment evaluation of the distal jet appliance" 120 : 178-85, 2001

      13 Ten Hoeve A, "Palatal bar and lip bumper in nonextraction treatment" 19 : 272-91, 1985

      14 Smalley WM, "Osseointegrated titanium implants for maxillofacial protraction in monkeys" 94 : 285-95, 1988

      15 Papadopoulos MA, "Orthodontic treatment of Class II malocclusion with miniscrew implants" 134 : e1-16, 2008

      16 Turley PK, "Orthodontic force application to titanium endosseous implants" 58 : 151-62, 1988

      17 Björk A, "Normal and abnormal growth of the mandible. A synthesis of longitudinal cephalometric implant studies over a period of 25 years" 5 : 1-46, 1983

      18 Wilson WL, "Multi-directional 3D functional Class II treatment" 21 : 186-9, 1987

      19 Locatelli R, "Molar distalization with superelastic NiTi wire" 26 : 277-9, 1992

      20 Jeckel N, "Molar distalization by intra-oral force application" 3 : 43-6, 1991

      21 Keles A, "Maxillary unilateral molar distalization with sliding mechanics: a preliminary investigation" 23 : 507-15, 2001

      22 Kircelli BH, "Maxillary molar distalization with a bone-anchored pendulum appliance" 76 : 650-9, 2006

      23 Gelgör IE, "Intraosseous screw-supported upper molar distalization" 74 : 838-50, 2004

      24 Bolla E, "Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods" 72 : 481-94, 2002

      25 Ghosh J, "Evaluation of an intraoral maxillary molar distalization technique" 110 : 639-46, 1996

      26 Kinzinger GS, "Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization" 136 : 578-86, 2009

      27 Kinzinger GS, "Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage" 125 : 8-23, 2004

      28 Escobar SA, "Distalization of maxillary molars with the bone-supported pendulum: a clinical study" 131 : 545-9, 2007

      29 Gianelly AA, "Distal movement of the maxillary molars" 114 : 66-72, 1998

      30 Byloff FK, "Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation" 67 : 249-60, 1997

      31 Angelieri F, "Dentoalveolar and skeletal changes associated with the pendulum appliance followed by fixed orthodontic treatment" 129 : 520-7, 2006

      32 Gulati S, "Dental and skeletal changes after intraoral molar distalization with sectional jig assembly" 114 : 319-27, 1998

      33 Keles A, "Bodily distalization of molars with absolute anchorage" 73 : 471-82, 2003

      34 Keles A, "Bilateral maxillary molar distalization with sliding mechanics: Keles slider" 3 : 57-66, 2002

      35 Runge ME, "Analysis of rapid maxillary molar distal movement without patient cooperation" 115 : 153-7, 1999

      36 Keles A, "A new approach in maxillary molar distalization: intraoral bodily molar distalizer" 117 : 39-48, 2000

      37 Worms FW, "A concept and classifications of centers of rotation and extraoral force systems" 43 : 384-401, 1973

      38 Chiu PP, "A comparison of two intraoral molar distalization appliances: distal jet versus pendulum" 128 : 353-65, 2005

      39 Staggers JA, "A comparison of results of second molar and first premolar extraction treatment" 98 : 430-6, 1990

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2002-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.13 0.47 0.83
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.67 0.55 0.311 0.24
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼