<P><B>Abstract</B></P> <P>Airborne particulate matter (PM) is closely linked to a range of adverse health outcomes such as oxidative stress-induced DNA damage and respiratory symptoms. A number of young children aged und...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107743302
2017
-
SCOPUS,SCIE
학술저널
1-10(10쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P><B>Abstract</B></P> <P>Airborne particulate matter (PM) is closely linked to a range of adverse health outcomes such as oxidative stress-induced DNA damage and respiratory symptoms. A number of young children aged und...
<P><B>Abstract</B></P> <P>Airborne particulate matter (PM) is closely linked to a range of adverse health outcomes such as oxidative stress-induced DNA damage and respiratory symptoms. A number of young children aged under 5 years spend a significant amount of time in nurseries worldwide. However, few studies examine children's exposure to PM in nursery environments. The objective of this study is to characterize five important metrics of particulate matter pollutants in urban nurseries in a mega-city, Seoul, Korea during winter days. 48 h field measurements were performed at four urban nurseries to monitor size-resolved particle number (PN) concentration (10–700 nm), lung-deposited surface area (LDSA, 10–1000 nm), and mass concentrations of PM<SUB>2.5</SUB>, PM<SUB>10</SUB>, and black carbon (BC). Other environmental parameters such as CO<SUB>2</SUB> concentration, temperature, and relative humidity (RH) were measured. Results show that indoor PN concentrations and LDSA are notably elevated during occupancy, mainly due to window opening. During window-open periods, the geometric mean of indoor particle size distribution is in the range of 30–40 nm, similar to the geometric mean of the outdoor particle size distribution. For all nurseries, the daily-integrated exposure to PN had an overall mean of 170 × 10<SUP>3</SUP>/cm<SUP>3</SUP> h/day and a relative standard deviation of 32%. The indoor mean concentrations of BC and LDSA during occupancy is comparable to those of busy roads in populated cities such as Zurich, Lisbon and Barcelona, suggesting high potential for lung deposition of UFP in nursery classrooms.</P> <P><B>Highlights</B></P> <P> <UL> <LI> We examine children's exposure to particulate matter in urban nurseries. </LI> <LI> Indoor ultrafine PM and black carbon levels are sensitive to window opening. </LI> <LI> High potential for lung deposition of UFP is observed in urban nurseries. </LI> <LI> Improved ventilation is needed to limit exposure to particles in urban nurseries. </LI> </UL> </P>