The instantaneous wan temperature and heat flux of the Piston crown, ring groove and land are measured and analyzed It was found that (i) the instantaneous wall temperature of the valve pocket, in the piston crown, is higher than that of the center of...
The instantaneous wan temperature and heat flux of the Piston crown, ring groove and land are measured and analyzed It was found that (i) the instantaneous wall temperature of the valve pocket, in the piston crown, is higher than that of the center of the crown and the edge of the crown is lowest; (ii) the instantaneous temperature of the top-ring groove and land are changed simi1ar to that of the piston crown, which are influenced by the behaivar of the piston ring; (iii) the distributions of the heat flux are not coincided with the wall surface temperature, which are depended on the f1ame distance, combustion condition, behavior of the piston ring and the state of cooling, etc