      난류 발생기의 형상에 따른 수직 PCB채널에서의 열전달 및 압력손실 변화 = Heat transfer and pressure drop with the turbulence promoter in a vertical PCB Channel

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study was performed to analyze the cooling effect of heated ribs which are frequently used for cooling of electronic parts, using the numerical method. To prevent the excessive pressure drop due to turbulence promoters for the enhancement of heat...

      This study was performed to analyze the cooling effect of heated ribs which are frequently used for cooling of electronic parts, using the numerical method. To prevent the excessive pressure drop due to turbulence promoters for the enhancement of heat transfer rate especially, the effect of the angle of turbulence promoter was investigated by the numerical analysis. Heat transfer rate with turbulence promoters with rectangular cross-section increased by 13% in average, but the coefficient of pressure drop increased by 1.68 times than that without them. In the present study, triangular cross-sectional shape turbulence promoters were suggested and numerically tested. Pressure drop of turbulence promoter with the 30 degree triangular cross-sectional shape decreased by 30% from that of rectangular cross-section promoters while heat transfer rate was almost the same. While with 4 turbulence promoters, the heat transfer rate increased by 21%, the pressure drop increased 4 times. It means that the higher capacity of cooling fan should be needed. With the triangular cross-sectional shape, the size of vortex region at the rear of promoters became considerably smaller, so pressure drop became smaller. The effect of the change of cross-sectional shape was not found in the flow pattern near the ribs, so that heat transfer characteristics in the ribs were not changed.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼