<P>Phospholipids make up one of the more important classes of biological molecules. Because of their amphipathic nature and their charge state (<I>e.g.</I>, negatively charged or zwitterionic) detection of trace levels of these compo...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107758002
2011
-
SCOPUS,SCIE
학술저널
1586-1593(8쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>Phospholipids make up one of the more important classes of biological molecules. Because of their amphipathic nature and their charge state (<I>e.g.</I>, negatively charged or zwitterionic) detection of trace levels of these compo...
<P>Phospholipids make up one of the more important classes of biological molecules. Because of their amphipathic nature and their charge state (<I>e.g.</I>, negatively charged or zwitterionic) detection of trace levels of these compounds can be problematic. Electrospray ionization mass spectrometry (ESI-MS) is used in this study to detect very small amounts of these analytes by using the positive ion mode and pairing them with fifteen different cationic ion pairing reagents. The phospholipids used in this analysis were phosphatidylethanolamine (PE), phosphatidylcholine (PC), phosphatidylglycerol (PG), phosphatidylserine (PS), phosphatidylinositol (PI), phosphatidic acid (PA), 1,2-diheptanoyl-<I>sn</I>-<I>glycero</I>-3-phosphocholine (DHPC), cardiolipin (CA) and sphingosyl phosphoethanolamine (SPE). The analysis of these molecules was carried out in the single ion monitoring (SIM) positive mode. In addition to their detection, a high performance liquid chromatography and mass spectrometry (HPLC-MS) method was developed in which the phospholipids were separated and detected simultaneously within a very short period of time. Separation of phospholipids was developed in the reverse phase mode and in the hydrophilic interaction liquid chromatography (HILIC) mode HPLC. Their differences and impact on the sensitivity of the analytes are compared and discussed further in the paper. With this technique, limits of detection (LODs) were very easily recorded at low ppt (ng L<SUP>−1</SUP>) levels with many of the cationic ion pairing reagents used in this study.</P> <P>Graphic Abstract</P><P>This process shows the complex formation of the phospholipids and the cationic ion pairing reagents, while being electrosprayed and detected in the positive ion mode ESI-MS.
<IMG SRC='http://pubs.rsc.org/services/images/RSCpubs.ePlatform.Service.FreeContent.ImageService.svc/ImageService/image/GA?id=c0an00848f'>
</P>