RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS

      Influence of Service Characteristics on High Priority Performance Indicators and Standards in the BreastScreen Australia Program

      한글로보기

      https://www.riss.kr/link?id=A101652135

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background: Data from BreastScreen Australia Screening and Assessment Services (SAS) for 2002-2010 were analysed to determine whether some SAS characteristics were more conducive that others to high screening performance, as indicated by high priority...

      Background: Data from BreastScreen Australia Screening and Assessment Services (SAS) for 2002-2010 were analysed to determine whether some SAS characteristics were more conducive that others to high screening performance, as indicated by high priority performance indicators and standards. Materials And Methods: Indicators investigated related to: numbers of benign open biopsies, screen-detected invasive cancers, and interval cancers, and wait times between screening and assessment. Multivariate Poisson regression was undertaken using as candidate predictors of performance, SAS size (screening volume), urban or rural location, year of screening, accreditation status, and percentages of clients from culturally and linguistically diverse backgrounds, rural and remote areas, and socio-economically disadvantaged areas. Results: Performance standards for benign biopsies and invasive cancer detection were uniformly met irrespective of SAS location and size. The interval cancer standard was also met, except in 2003 when the 95% confidence interval of the rate still incorporated the national standard. Performance indicators improved over time for: benign open biopsy for second or subsequent screening rounds; rates of invasive breast cancer detection for second or subsequent screening rounds; and rates of small cancer detection. No differences were found over time in interval cancer rates. Interval cancer rates did not differ between non-metropolitan and metropolitan SAS, although state-wide SAS had lower rates. The standard for wait time between screening and assessment (being assessed ${\leq}28$ days) was mostly unmet and this applied in particular to SAS with high percentages of culturally and linguistically diverse women in their screening populations. Conclusions: Gains in performance were observed, and all performance standards were met irrespective of SAS characteristics, except wait times to assessment. Additional descriptive data should be collected on SAS characteristics, and their associations with favourable screening performance, as these may be important when deciding on SAS design

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼