      상수관로의 유속계수 설계기준

      한글로보기

      https://www.riss.kr/link?id=A103323459

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.
      번역하기

      In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of wate...

      In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.

      더보기

      참고문헌 (Reference)

      1 AWWA, "Water Treatment Plant Design" McGraw-Hill 2012

      2 Walski, T. M., "Water Distribution Systems: Simulation and Sizing" Lewis Publishers 1990

      3 Jones, G. M., "Pumping Station Design" Butterworth-Heinemann 2008

      4 Ministry of Environment, "Optimum management technology for water and wastewater system"

      5 AWWA, "Manual M11-Steel Pipe" American Water Works Association 2004

      6 JWWA, "Japanese design guideline for water pipe system"

      7 Korea Ductile Iron Pipe Association, "Handbook of Ductile Iron Pipe"

      8 Kim, J. H, "Development of Rehabilitation and Management Techniques for Old Water Distribution Systems" 3 : 197-205, 1996

      9 Ministry of Environment, "Design criteria for water pipe system"

      10 KWATER, "Design criteria for water pipe system"

      1 AWWA, "Water Treatment Plant Design" McGraw-Hill 2012

      2 Walski, T. M., "Water Distribution Systems: Simulation and Sizing" Lewis Publishers 1990

      3 Jones, G. M., "Pumping Station Design" Butterworth-Heinemann 2008

      4 Ministry of Environment, "Optimum management technology for water and wastewater system"

      5 AWWA, "Manual M11-Steel Pipe" American Water Works Association 2004

      6 JWWA, "Japanese design guideline for water pipe system"

      7 Korea Ductile Iron Pipe Association, "Handbook of Ductile Iron Pipe"

      8 Kim, J. H, "Development of Rehabilitation and Management Techniques for Old Water Distribution Systems" 3 : 197-205, 1996

      9 Ministry of Environment, "Design criteria for water pipe system"

      10 KWATER, "Design criteria for water pipe system"

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-12-28 학술지명변경 외국어명 : Journal of the Korean Society of Water and Wastewater -> Journal of Korean Society of Water and Wastewater KCI등재
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.2 0.2 0.21
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.19 0.15 0.342 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼