In the 4DCT era, the definition of lung organ‐at‐risk (OAR) volumes for dose–volume histogram (DVH) calculation is unclear, introducing potential for variability in practice. We aimed to identify definitions used clinically and evaluate the magn...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=O112502198
2020년
-
1754-9477
1754-9485
SCOPUS;SCIE
학술저널
120-126 [※수록면이 p5 이하이면, Review, Columns, Editor's Note, Abstract 등일 경우가 있습니다.]
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
In the 4DCT era, the definition of lung organ‐at‐risk (OAR) volumes for dose–volume histogram (DVH) calculation is unclear, introducing potential for variability in practice. We aimed to identify definitions used clinically and evaluate the magn...
In the 4DCT era, the definition of lung organ‐at‐risk (OAR) volumes for dose–volume histogram (DVH) calculation is unclear, introducing potential for variability in practice. We aimed to identify definitions used clinically and evaluate the magnitude of DVH differences between these.
We surveyed Australian & New Zealand departments about lung radiotherapy protocols including lung OAR volume definition. We used these definitions to calculate lung DVHs on 10 patients prescribed lung IMRT (60–66 Gy/30–33 fractions). We calculated mean lung dose (MLD), V20 and V30 for ‘Lungs – PTV’, ‘Lungs – CTV’, ‘Lungs – iGTV’ (internal GTV in all respiratory phases) and ‘Lungs – GTV_EX’ (expiratory phase).
The response rate was 39% (34/88). 14% and 29% of departments did not have a departmental protocol for OAR and tumour volume delineation, respectively. All permutations for lung OAR volumes were used with no clear preference. For conventional radiotherapy (n = 27), this included Lungs alone (n = 1), Lungs – PTV (n = 6), Lungs – CTV (n = 2), Lungs – iGTV (n = 6), Lungs – GTV in single phase (n = 5) and individual clinician preference (n = 7). The different lung OAR volumes resulted in MLD difference ranging from 0.9 to 4.15 Gy, V20 from 1.5% to 6.6% and V30 from 1.34% to 7.11%. The largest differences between subtraction of GTV_EX and iGTV were 0.32 Gy, 0.43% and 0.46% for MLD, V20 and V30, respectively.
A significant number of departments lacked lung cancer radiotherapy contouring protocols. Lung OAR volume definition was variable between and within departments. Potentially clinically significant differences in lung DVH parameters were seen according to the volume used.