RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCIE KCI등재

      Evaluation of Sensitivity and Linearity for Touch-mode Capacitive Pressure Sensor Measuring the Inner Bladder Pressure

      한글로보기

      https://www.riss.kr/link?id=A107567647

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recent studies have shown that pressure sensors for monitoring bladder pressure in real time are under way to develop treatments for urinary bladder dysfunction. Therefore, this study is designed to assess the sensitivity and linearity of touch-mode c...

      Recent studies have shown that pressure sensors for monitoring bladder pressure in real time are under way to develop treatments for urinary bladder dysfunction. Therefore, this study is designed to assess the sensitivity and linearity of touch-mode capacitive pressure sensor (TMCPS), which is appropriate for measuring urinary bladder pressure. In addition, this study analyzes TMCPS's ability responding to geometric design parameters. Finite element model consists of diaphragm and insulator plane. The modeling is based on three geometric design variables: size of square diaphragm, thickness of diaphragm and gap distance between diaphragm and insulator. The result from finite element analysis (FEA) based on those design variables can be used to produce capacitance-pressure (C-P) graph and the first order regression curve enables this study to analyze the sensitivity and linearity within 20~100cm$H_2O$ which is the measurable range of urinary bladder pressure. Regarding the effect on the thickness of diaphragm under the gap distance of 4 ${\mu}m$ corresponding to the square size of 2.6mm, this research shows that remarkable decline in sensitivity from 0.0031pF/cm$H_2O$ to 0.0022pF/cm$H_2O$ occurs as thickness increases from 11 ${\mu}m$ to 15 ${\mu}m$. Even in the case of 5 ${\mu}m$ gap distance, sensitivity is shown to decrease from 0.0032pF/cm$H_2O$ to 0.0015pF/cm$H_2O$ as thickness increases from 11 ${\mu}m$ to 15 ${\mu}m$. From a linearity point of view, however, it always marks higher value than 0.9 regardless of its thickness and describes relatively small deviation under 3.0mm. The study shows that as the size of diaphragm gets larger, sensitivity increases but linearity decreases. In addition, the thicker the diaphragm is, the less sensitivity the sensors are. However, the change in linearity turns out to be invalid. This research could be helpful in designing a touch-mode capacitive pressure sensor for urinary bladder pressure measurement.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼