RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      하악우각부 골절의 골내고정후 응력분포에 관한 3차원 유한요소법적 연구 = The 3-d fem stress anaylsis of the internal fixation for the fracture of mandibular angle

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      It has been considered that tension is developed onto the superior border(along the osteosynthesis line) and compression presents at the inferior border of the mandible when the occlusal load is applied at the two dimensional model of the fractured ma...

      It has been considered that tension is developed onto the superior border(along the osteosynthesis line) and compression presents at the inferior border of the mandible when the occlusal load is applied at the two dimensional model of the fractured mandible. Therefore, the internal fixation with one miniplate on the external oblique ridge of the mandible insisted by Champy et ais. (1972) seemed to be adequate to stabilize the bone segments of the mandibular angle fractures.
      But many clinicians doubted that torque stress as well as compressive stress may be developed at the inferior border of 3-dimensional mandible during loading. Kroon et als(1991) reported that the torque stress must be controlled bv additional internal fixation to prevent torsion of the fraoments.
      This is an experimental design to study the stress distribution after the internal fixation with monocortical miniplates and additional devices. The 3-dimensional finite element measurement analysis was used with (1) one miniplate at the superior border(1MP), (2) two miniplates at the superior border and inferior border(2MP), and (3) one miniplate at the superior border and suspension wire-bridge at the inferior border(1MP-SW)
      The results are as following;
      (1) When the occlusal load is applied to the fractured posterior molar region, the stress distributions of 2MP and 1MP-SW are close to the unfractured model.
      (2) When the occlusal load is applied to fractured posterior molar region, the gap of displacement at the inferior border was more significant in 1MP than 2MP or 1MP-SW.
      (3) When the occlusal load is applied to un-fractured site, there are no differences in the stress distributions between 1MP, 2MP and 1MP-SW.
      (4) It can be concluded that the auxillary inferior suspension wiring is a good option in the management of mandibular angle fractures to resist the functional load and pevent the development of gap between the fractured segments.

      더보기

      목차 (Table of Contents)

      • Abstract
      • I. 서론
      • II. 연구재료 및 연구방법
      • III. 연구성적
      • IV. 고찰
      • Abstract
      • I. 서론
      • II. 연구재료 및 연구방법
      • III. 연구성적
      • IV. 고찰
      • IV. 결론
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼