RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      더러브렛 경주마에서 혈청 젖산농도 측정에 의한 표준운동능력검사의 적용 = Application of a standardized exercise test by measuring serum lactate concentration in Thoroughbred racehorses

      한글로보기

      https://www.riss.kr/link?id=A106132870

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      To establish the protocol of a standardized exercise test for evaluating exercise intolerance and degree of fitness in Thoroughbred racehorses, we examined serum lactate concentrations related to exercise intensities using the high speed treadmill. Tw...

      To establish the protocol of a standardized exercise test for evaluating exercise intolerance and degree of fitness in Thoroughbred racehorses, we examined serum lactate concentrations related to exercise intensities using the high speed treadmill. Twelve clinically healthy Thoroughbred racehorses with or without previous training or racing history were assigned to two gorups, fit and unfit group, respectively. The protocol used for the standardized exercise test was consisted of two stages : stage of warm-up and that of acceleration. During the warm-up, the horses exercised 5 min at 1.8m/s and 3 min 3.4m/s without inclination. At the acceleration stage, exercise test was performed at 10% slope and the speed was increased from the initial 5m/s to the maximal speed which each tested horse could keep up with. The speed was increased with incremental steps of 1 m/s every minute. During the last 15 sec of each step, blood samples were collected for serum lactate determination. $V_{max}$(maximal treadmill speed which tested horses could keep up with) of the fit group ($10.93{\pm}0.33m/s$, mean${\pm}$SE, n = 6) was higher than that of the unfit group ($9.52{\pm}0.23m/s$, mean${\pm}$SE, n = 6). Serum lactate concentrations increased exponentially according to exercise intensities. $V_{La4}$(speed producing a serum lactate concentration of 4mmol/l) of the fit group, $6.45{\pm}0.26m/s$, was higher than that of the unfit group, $5.45{\pm}0.23m/s$. $La_{peak}$(peak plasma lactate concentration during the exercise test) was lower in the fit group ($20.34{\pm}1.62mmol/l$ at 1 min after maximal intensity exercise) than in the unfit group ($24.78{\pm}1.09mmol/l$ at 2 min after maximal exercise step). $t_{50%}$(time required for the recovery of lactate concentration to be one-half of $La_{peak}$ after maximal exercise) of the unfit group and the fit group were 40.0 and 18.0 min, respectively. Therefore, the protocol of the incremental standardized exercise test utilized in this study seems to be reliable for the assessment of fitness and exercise intolerance for the Thoroughbred racehorses.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼