      Comparison of orbital prosthesis motility following enucleation or evisceration with sclerotomy with or without a motility coupling post in dogs

      한글로보기

      https://www.riss.kr/link?id=A107597331

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>Abstract</P><P>Objective </P><P>To evaluate motility of silicone orbital implants and corneoscleral prostheses, with and without use of a motility coupling post (MCP) in dogs.</P><P>Animals studied&ens...

      <P>Abstract</P><P>Objective </P><P>To evaluate motility of silicone orbital implants and corneoscleral prostheses, with and without use of a motility coupling post (MCP) in dogs.</P><P>Animals studied </P><P>Eighteen mixed-breed dogs.</P><P>Procedures </P><P>The motility of an orbital silicone implant and corneoscleral prosthesis after enucleation (<I>n</I> = 6), evisceration (<I>n</I> = 6), or use of a MCP with evisceration (<I>n</I> = 6) in dogs were compared. One eye from each dog had surgery whereas the opposite eye was used as a control. Clinical evaluations were performed three times a week. Histopathology of the orbital tissues was performed 8 and 12 weeks after surgery.</P><P>Results </P><P>Implant motility in dogs with evisceration (vertical movement [VM] 8.04 ± 2.13; horizontal movement [HM] 11 ± 3.05) and evisceration with MCP (VM 9.61 ± 1.59); HM was significantly greater than the enucleation group (VM 0.51 ± 0.5; HM 1.22 ± 0.68) (<I>P <</I> 0.01). Prosthetic motility in dogs with evisceration with MCP was significantly greater than in dogs with evisceration; dogs with evisceration had significantly greater motility than dogs with enucleation (<I>P <</I> 0.01). No postoperative complications were observed in any of the groups. No significant abnormalities were noted on histopathology.</P><P>Conclusions </P><P>MCP placement in silicone orbital implants significantly enhanced the prosthetic motility in dogs. This study supports the use of MCP in silicone orbital implants to enhance corneoscleral prosthesis motility and cosmetics in dogs.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼