RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Simultaneous and Interference-Free Detection of Hydroquinone and Catechol on Poly (Evans Blue)-Modified Glassy Carbon Electrode

      한글로보기

      https://www.riss.kr/link?id=A107735290

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>A simple and sensitive electrochemical sensor for the simultaneous detection of hydroquinone (HQ) and catechol (CT) is developed based on a poly (Evans blue) (PEB)-modified anodized glassy carbon electrode (AGCE). The PEB/AGCE sensor shows ex...

      <P>A simple and sensitive electrochemical sensor for the simultaneous detection of hydroquinone (HQ) and catechol (CT) is developed based on a poly (Evans blue) (PEB)-modified anodized glassy carbon electrode (AGCE). The PEB/AGCE sensor shows excellent electrocatalytic activity and reversibility toward the oxidation of both HQ and CT in phosphate buffer solution (PBS, pH 7.0). Both AGCE and PEB/AGCE can easily resolve the redox responses of HQ and CT from their mixture solution with the same peak-to-peak potential (Delta Ep) separations of ca. 0.10 V, whereas bare GCE cannot resolve them. The PEB/AGCE sensor exhibits significantly higher sensitivity with a linear dynamic range 1-100 mu M for both HQ and CT. Furthermore, the sensor shows detection limits (S/N = 3) of ca. 0.13 and 0.12 mu M for HQ and CT, respectively, with sensitivities of ca. 1.01 and 0.95 mu A/cm(2)/mu M, respectively. The sensor does not exhibit any significant interference for the detection of HQ and CT in the presence of common interferences. This study provides a simple and sensitive method with excellent recoveries for the simultaneous and quantitative determination of HQ and CT from tap water. (C) 2016 The Electrochemical Society. All rights reserved.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼