RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Finite element analysis of stress distribution around a short implant according to a horizontally reduced bone in the mandible = Finite element analysis of stress distribution around a short implant according to a horizontally reduced bone in the mandible

      한글로보기

      https://www.riss.kr/link?id=A107354407

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study evaluates the stress distribution around a short implant supporting a bone with various horizontally reduced levels using a three-dimensional finite element stress analysis. A three-dimensional finite element model was designed by placing a...

      This study evaluates the stress distribution around a short implant supporting a bone with various horizontally reduced levels using a three-dimensional finite element stress analysis. A three-dimensional finite element model was designed by placing a short implant in a jaw model with a 2-mm-thick cortical bone. Horizontal bone loss was employed at 1-mm intervals from 0 to 3 mm, and a 400- N load was applied to the central fossa in a 0° vertical direction and 30° inward-inclined direction to the implant axis. Furthermore, the maximum principal stress generated in the short implant supporting the bone was calculated using a three-dimensional finite element stress analysis. As a result of the finite element analysis, the maximum principal stresses in a 0° vertical direction according to horizontal bone loss from 1 mm to 3 mm in the cortical bone were 45.13, 79.44, and 75.53 (MPa), respectively, and in the cancellous bone were 7.63, 9.28, and 9.60 (MPa), respectively. The maximum principal stresses in a 30° inward-inclined direction according to horizontal bone loss from 1 mm to 3 mm in the cortical bone were 132.34, 172.07, and 216.26 (MPa), respectively, and in the cancellous bone were 16.34, 27.43, and 26.37 (MPa), respectively. Within the limitations of this study, the authors concluded that the bone stress values tended to be higher around the implant neck under a 30° inward load and in the cortical bone according to the horizontally reduced bone level.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼