RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      구조용단열패널의 정적가력과 반복가력 성능 평가 = Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels

      한글로보기

      https://www.riss.kr/link?id=A101669369

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are ...

      Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

      더보기

      참고문헌 (Reference)

      1 Edward, L. K., "Standardization Tesing of Structural Insulated Panels(SIPs) for The Structural Insulated Panel Association" APA-The Engineered Wood Association 4-13, 2006

      2 Durham, J., "Seismic Resistance of Wood Shear Walls with Large OSB Panels" ASCE 127 (127): 1460-1466, 2001

      3 Mosalam, K. M., "Seismic Evaluation of Structural Insulated Panels" ASCE 2008

      4 U. S. Department of Housing and Urban Development, "Prescriptive Method for Structural Insulated Panels (SIPs) Used in Wall Systems in Residential Construction"

      5 Nah, H. S., "Evaluation on Structural Performance of Structural Insulated Panels. in Wall Application" 3 (3): 19-27, 2012

      6 Borjen, Y., "Development of structural insulated panel standards" ASCE 2008

      7 Krawinkler, H., "Development of a Testing Protocol for Woodframe Structures" CUREE Publication 2000

      8 He, M., "Cyclic Performance of Perforated Wood Shear Walls with Oversize OSB Panels" ASCE 125 (125): 10-18, 1999

      9 "ANSI/APA PRS-610.1 Draft 4, Standard for Performance-Rated Structural Insulated Panels in Wall Applications. APA-The Engineered Wood Association"

      1 Edward, L. K., "Standardization Tesing of Structural Insulated Panels(SIPs) for The Structural Insulated Panel Association" APA-The Engineered Wood Association 4-13, 2006

      2 Durham, J., "Seismic Resistance of Wood Shear Walls with Large OSB Panels" ASCE 127 (127): 1460-1466, 2001

      3 Mosalam, K. M., "Seismic Evaluation of Structural Insulated Panels" ASCE 2008

      4 U. S. Department of Housing and Urban Development, "Prescriptive Method for Structural Insulated Panels (SIPs) Used in Wall Systems in Residential Construction"

      5 Nah, H. S., "Evaluation on Structural Performance of Structural Insulated Panels. in Wall Application" 3 (3): 19-27, 2012

      6 Borjen, Y., "Development of structural insulated panel standards" ASCE 2008

      7 Krawinkler, H., "Development of a Testing Protocol for Woodframe Structures" CUREE Publication 2000

      8 He, M., "Cyclic Performance of Perforated Wood Shear Walls with Oversize OSB Panels" ASCE 125 (125): 10-18, 1999

      9 "ANSI/APA PRS-610.1 Draft 4, Standard for Performance-Rated Structural Insulated Panels in Wall Applications. APA-The Engineered Wood Association"

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2017-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2016-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2014-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.23 0.23 0.26
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0 0 0.464 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼