본 연구의 목적은 동적하중 하에서 네 종류의 근관치료용 임시충전재의 밀폐효과를 비교하는 것이다. 44개의 건전한 인간 대구치에 표준차된 근관와동을 형성한 후 Caviton, MD-Temp, IRM 및 ZOE를 ...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A75056719
Jung, Dong-Ho (Department of Conservative Dentistry, College of Dentistry, Wonkwang University) ; Noh, Young-Sin (Department of Conservative Dentistry, College of Dentistry, Wonkwang University) ; Lee, Hae-Doo (Department of Conservative Dentistry, College of Dentistry, Wonkwang University) ; Chang, Hoon-Sang (Department of Conservative Dentistry, College of Dentistry, Wonkwang University) ; Ryu, Hyun-Wook (Department of Conservative Dentistry, College of Dentistry, Wonkwang University) ; Min, Kyung-San (Department of Conservative Dentistry, College of Dentistry, Wonkwang University)
2008
English
515
KCI등재
학술저널
198-203(6쪽)
0
상세조회0
다운로드국문 초록 (Abstract)
본 연구의 목적은 동적하중 하에서 네 종류의 근관치료용 임시충전재의 밀폐효과를 비교하는 것이다. 44개의 건전한 인간 대구치에 표준차된 근관와동을 형성한 후 Caviton, MD-Temp, IRM 및 ZOE를 ...
본 연구의 목적은 동적하중 하에서 네 종류의 근관치료용 임시충전재의 밀폐효과를 비교하는 것이다. 44개의 건전한 인간 대구치에 표준차된 근관와동을 형성한 후 Caviton, MD-Temp, IRM 및 ZOE를 이용하여 충전하였다. 이 후, 1% 메틸렌블루 용액에 담근 상태에서 반복하중기를 이용하여 I Hz의 속도로 98 N의 하중을 기능교두에 1,000번 가한 다음 시편을 양분해 미세누출을 평가하고 one-way ANOVA (p = 0.05)와 사후 검정으로 Duncan' s multiple range tests로 통계분석 하였다. Caviton군과 MD-Temp군이 IRM군과 ZOE군보다 통계적으로 적은 미세누출을 보였으며 (p < 0.05), 본 실험결과로 볼 때 Caviton과 MD-Temp가 IRM과 ZOE보다 동적하중 하에서 근관와동 밀폐효과가 우수하다고 사료된다.
다국어 초록 (Multilingual Abstract)
The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human ...
The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan' s multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.
Polymerization of dual cured composites by different thickness
복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구
Resilon을 이용한 근관충전 시 레진계열의 근관실러와 자가-접착 레진시멘트에 따른 미세누출