RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Transaxillary Subpectoral Placement of Cardiac Implantable Electronic Devices in Young Female Patients

      한글로보기

      https://www.riss.kr/link?id=A103548754

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach.
      Methods From July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of 20.1 kg/m2. In the supine position, with the patient’s shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases.
      The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously.
      Results One case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others.
      Conclusions With superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.
      번역하기

      Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the ...

      Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach.
      Methods From July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of 20.1 kg/m2. In the supine position, with the patient’s shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases.
      The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously.
      Results One case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others.
      Conclusions With superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.

      더보기

      참고문헌 (Reference)

      1 Shefer A, "The retropectoral transaxillary permanent pacemaker : description of a technique for percutaneous implantation of an"invisible"device" 19 : 1646-1651, 1996

      2 Giudici MC, "Submammary pacemakers and ICDs in women : long-term follow-up and patient satisfaction" 33 : 1373-1375, 2010

      3 Kolettis TM, "Submammary implantation of a cardioverter-defibrillator with nonthoracotomy lead system" 126 : 1222-1223, 1993

      4 Hammill SC, "Review of the registry’s fourth year, incorporating lead data and pediatric ICD procedures, and use as a national performance measure" 7 : 1340-1345, 2010

      5 Thomas SA, "Quality of life and psychological status of patients with implantable cardioverter defibrillators" 15 : 389-398, 2006

      6 Molina JE, "New technique for pacemaker implantation in the upper chest of children and women" 51 : 992-995, 1991

      7 Connolly SJ, "Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials: AVID, CASH and CIDS studies: Antiarrhythmics vs Implantable Defibrillator Study: Cardiac Arrest Study Hamburg: Canadian Implantable Defibrillator Study" 21 : 2071-2078, 2000

      8 Belott PH, "Inframammary pulse generator placement for maximizing cosmetic effect" 6 : 1241-1244, 1983

      9 Schaverien MV, "Inframammary cardiac pacemaker insertion in women: an aesthetic alternative" 131 : 464e-465e, 2013

      10 Ozin B, "Implantation of submammary implantable cardioverter defibrillators" 27 : 779-782, 2004

      1 Shefer A, "The retropectoral transaxillary permanent pacemaker : description of a technique for percutaneous implantation of an"invisible"device" 19 : 1646-1651, 1996

      2 Giudici MC, "Submammary pacemakers and ICDs in women : long-term follow-up and patient satisfaction" 33 : 1373-1375, 2010

      3 Kolettis TM, "Submammary implantation of a cardioverter-defibrillator with nonthoracotomy lead system" 126 : 1222-1223, 1993

      4 Hammill SC, "Review of the registry’s fourth year, incorporating lead data and pediatric ICD procedures, and use as a national performance measure" 7 : 1340-1345, 2010

      5 Thomas SA, "Quality of life and psychological status of patients with implantable cardioverter defibrillators" 15 : 389-398, 2006

      6 Molina JE, "New technique for pacemaker implantation in the upper chest of children and women" 51 : 992-995, 1991

      7 Connolly SJ, "Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials: AVID, CASH and CIDS studies: Antiarrhythmics vs Implantable Defibrillator Study: Cardiac Arrest Study Hamburg: Canadian Implantable Defibrillator Study" 21 : 2071-2078, 2000

      8 Belott PH, "Inframammary pulse generator placement for maximizing cosmetic effect" 6 : 1241-1244, 1983

      9 Schaverien MV, "Inframammary cardiac pacemaker insertion in women: an aesthetic alternative" 131 : 464e-465e, 2013

      10 Ozin B, "Implantation of submammary implantable cardioverter defibrillators" 27 : 779-782, 2004

      11 Hammel D, "Implantation of a cardioverter/defibrillator in the subpectoral region combined with a nonthoracotomy lead system" 15 : 367-368, 1992

      12 Goldberger Z, "Implantable cardioverter-defibrillators:expanding indications and technologies" 295 : 809-818, 2006

      13 Giudici MC, "Experience with a cosmetic approach to device implantation" 24 : 1679-1680, 2001

      14 Sears SF Jr, "Examining the psychosocial impact of implantable cardioverter defibrillators : a literature review" 22 : 481-489, 1999

      15 Asamura S, "Efficacy and feasibility of the submuscular implantation technique for an implantable cardiac electrical device" 14 : e40-, 2014

      16 Marshall P, "Comparison of male and female psychological outcomes related to implantable cardioverter defibrillators(COMFORTID)" 11 : 313-321, 2012

      17 Allan D, "Augmentation mammaplasty approach to pacemaker implantation" 15 : 242-243, 1985

      18 Vazquez LD, "Age-specific differences in women with implantable cardioverter defibrillators : an international multi center study" 31 : 1528-1534, 2008

      19 Persichetti P, "Aesthetic subpectoral placement of implantable cardioverter defibrillators" 72 : 188-192, 2014

      20 Rosenthal E, "A cosmetic approach for pectoral pacemaker implantation in young girls" 23 : 1397-1400, 2000

      21 "A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias: the Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators" 337 : 1576-1583, 1997

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-01-15 학술지명변경 한글명 : 대한성형외과 학회지 -> Archives of Plastic Surgery
      외국어명 : Journal of The Korean Society of Plastic and Reconstructive Surgeons -> Archives of Plastic Surgery
      KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.12 0.11 0.335 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼