RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    SCI SCIE SCOPUS

    Identification of low amount of irradiated spices (red pepper, garlic, ginger powder) with luminescence analysis

    한글로보기

    https://www.riss.kr/link?id=A107543154

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    <P><B>Abstract</B></P><P>For the identification of irradiated food, current analysis methods have limitations regarding presence and stability of radiation-induced markers. In this study, different spice blends with small quantity of different irradiated (0, 1 and 10kGy) spice powders, such as red pepper, garlic or ginger, were investigated using PSL and TL techniques. In PSL-based screening analysis, the spice blends containing 10% of irradiated materials (1 or 10kGy) were determined as intermediate or positive. In TL results, the blends containing 1% of 1 or 10kGy-irradiated spices showed the typical TL glow curves that could be interpreted as positive. The blends with irradiated garlic powder provided more good results where identification was possible at 0.5% mixing of irradiated sample. However, the TL ratios of all spice blends were <0.1 and only TL glow curve shape and intensity may be used to discriminate the samples having irradiated component.</P> <P><B>Highlights</B></P><P>► Sample blends with small quantities of irradiated spices were evaluated. ► The PSL was inappropriate to detect irradiated ingredient in small quantity. ► TL glow curve shape and intensity could be used as conclusive evidence of irradiation. ► TL ratios of all irradiated and nonirradiated samples were <0.1.</P>
    번역하기

    <P><B>Abstract</B></P><P>For the identification of irradiated food, current analysis methods have limitations regarding presence and stability of radiation-induced markers. In this study, different spice blends with small...

    <P><B>Abstract</B></P><P>For the identification of irradiated food, current analysis methods have limitations regarding presence and stability of radiation-induced markers. In this study, different spice blends with small quantity of different irradiated (0, 1 and 10kGy) spice powders, such as red pepper, garlic or ginger, were investigated using PSL and TL techniques. In PSL-based screening analysis, the spice blends containing 10% of irradiated materials (1 or 10kGy) were determined as intermediate or positive. In TL results, the blends containing 1% of 1 or 10kGy-irradiated spices showed the typical TL glow curves that could be interpreted as positive. The blends with irradiated garlic powder provided more good results where identification was possible at 0.5% mixing of irradiated sample. However, the TL ratios of all spice blends were <0.1 and only TL glow curve shape and intensity may be used to discriminate the samples having irradiated component.</P> <P><B>Highlights</B></P><P>► Sample blends with small quantities of irradiated spices were evaluated. ► The PSL was inappropriate to detect irradiated ingredient in small quantity. ► TL glow curve shape and intensity could be used as conclusive evidence of irradiation. ► TL ratios of all irradiated and nonirradiated samples were <0.1.</P>

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼