Recently, for the thermal system design in an engine room, the importance of the numerical analysis on the heat and fluid flow has been recognized. In the present study, the flow inside an engine room with complex geometry was analysed by use of TURBO...
Recently, for the thermal system design in an engine room, the importance of the numerical analysis on the heat and fluid flow has been recognized. In the present study, the flow inside an engine room with complex geometry was analysed by use of TURBO-3D program being developed in KIST. Radiator and Cooling fan were simulated by porous media and momentum sources, and the result shows a good agreement with our expectation.