      Development and Experimental Evaluation of Respiratory Assist Device by Use of Right Thoracic Negative Pressure Ventilation

      한글로보기

      https://www.riss.kr/link?id=A106010624

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      BACKGROUND: A diaphragm pacing with electrical stimulation is a new respiratory assist device which has advantages over mechanical ventilation. Unilateral phrenic nerve stimulation makes uneven distribution of intrathoracic negative pressure and most ...

      BACKGROUND: A diaphragm pacing with electrical stimulation is a new respiratory assist device which has advantages over mechanical ventilation. Unilateral phrenic nerve stimulation makes uneven distribution of intrathoracic negative pressure and most likely relates to paradoxical motion of the diaphragm. Our purpose is to investigate a respiratory effect of right phrenic nerve pacing after thoracotomy compared with bilateral pacing. METHODS: Five dogs were examined under the general anesthesia. Right 5th intercostal space was opened. Two pacing leads were placed around the phrenic nerve and connected to the stimulator. Chest wall was closed after chest tube insertion. Ventilator was off without self respiration. Swan-Ganz catheter was introduced to the pulmonary artery, cardiac output, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP). Arterial blood gases (PO2 & PCO2), end-tidal PCO2 (PETCO2) and tidal volume were measured with nerve stimulation. Left phrenic nerve was managed as the same manner. RESULTS: Right phrenic nerve pacing resulted in a tidal volume of 186+/-5 ml, PETCO2 of 55.0+/-2.3 mmHg, Arterial PO2 of 115+/-12 mmHg, PCO2 of 59+/-4 mmHg, Cardiac output of 2.3+/-0.5 L/min, CVP of 12.0+/-2.3 mmHg, PCWP of 14.2+/-2.5 mmHg. Bilateral phrenic nerve pacing resulted in a tidal volume of 418+/-3 ml, PETCO2 of 47.0+/-2.7 mmHg, PO2 of 289+/-10 mmHg, PCO2 of 42+/-3 mmHg, Cardiac output of 3.1+/-0.4 L/min, CVP of 10.2+/-2.5 mmHg, PCWP of 14.5+/-2.7 mmHg. Right phrenic nerve pacing showed significantly lower tidal volume, PO2 and higher PETCO2 and arterial blood PCO2 (p

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼