      자외선 영향을 받은 소프트 콘택트렌즈의 시감투과율 및 대비감도 변화에 대한 연구 = The Study on the Change of Luminous Transmittance and Contrast Sensitivity by Soft Contact Lens Affected Ultraviolet Rays

      한글로보기

      https://www.riss.kr/link?id=A104766704

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: In this study, the change of luminance transmittance and contrast sensitivity was studied by the change of UV cut-off soft contact lens according to increasing the exposure UV-A, UV-B, UV-CMethods: Luminance transmittance of two hydrogel lenses, two silicone hydrogel lenses which affected UV-A, B, C lamp was measured and the contrast sensitivity was examined to the patient 23(46 eyes)Results: The luminance transmittance of soft contact lens irradiated UV lamp greatly decreased from the lens irradiated by UV-C lamp to UV-B and UV-A.
      Contrast sensitivity test was performed to experimental subjects who wore soft contact lens affected by the same amount of ultraviolet irradiation.(9.35mJ/cm2) The measured value of lens irradiated by UV-C lamp was the lowest, which was a statistically significant difference(p<0.05).
      Conclusions: The change of luminance transmittance and contrast sensitivity of soft contact lens irradiated by ultraviolet A, B, C was affected by UV-C, UV-B, UV-A in regular sequence and silicone hydrogel material type was more affected than hydrogel material type.
      번역하기

      Purpose: In this study, the change of luminance transmittance and contrast sensitivity was studied by the change of UV cut-off soft contact lens according to increasing the exposure UV-A, UV-B, UV-CMethods: Luminance transmittance of two hydrogel lens...

      Purpose: In this study, the change of luminance transmittance and contrast sensitivity was studied by the change of UV cut-off soft contact lens according to increasing the exposure UV-A, UV-B, UV-CMethods: Luminance transmittance of two hydrogel lenses, two silicone hydrogel lenses which affected UV-A, B, C lamp was measured and the contrast sensitivity was examined to the patient 23(46 eyes)Results: The luminance transmittance of soft contact lens irradiated UV lamp greatly decreased from the lens irradiated by UV-C lamp to UV-B and UV-A.
      Contrast sensitivity test was performed to experimental subjects who wore soft contact lens affected by the same amount of ultraviolet irradiation.(9.35mJ/cm2) The measured value of lens irradiated by UV-C lamp was the lowest, which was a statistically significant difference(p<0.05).
      Conclusions: The change of luminance transmittance and contrast sensitivity of soft contact lens irradiated by ultraviolet A, B, C was affected by UV-C, UV-B, UV-A in regular sequence and silicone hydrogel material type was more affected than hydrogel material type.

      더보기

      국문 초록 (Abstract)

      목 적: 본 연구에서는 자외선 UV-A, UV-B, UV-C의 노출 증가에 따른 UV 차단용 소프트 콘택트렌즈의 시감투과율 및 대비감도의 변화에 미치는 영향에 대하여 연구하였다.
      방 법: UV-A, UV-B, UV-C lamp의 영향을 받은 2개의 하이드로겔 렌즈, 2개의 실리콘 하이드로겔 렌즈의 시감투과율과 피검자 23명(46안)의 대비감도를 검사하였다.
      결 과: UV lamp에 영향을 받은 콘택트렌즈의 시감투과율이 UV-C 조사받은 렌즈가 가장 크게 감소하였으며 UV-B, UV-A순으로 감소하였다. 동일한 자외선 양(9.35mJ/cm2)을 조사 받은 소프트 콘택트렌즈로 피검사자에게 착용 후 대비감도를 측정값은 UV-C 조사 받는 소프트 콘택트렌즈가 가장 낮게 측정되었고, 이는 통계적으로 유의한 차이를 보였다(p<0.05).
      결 론: UV-A, UV-B, UV-C lamp의 영향을 받은 소프트 콘택트렌즈의 시감투과율 및 대비감도 변화는 UV-C, UV-B, UV-A lamp 순으로 영향을 많이 받는 것을 알 수 있었고, 하이드로겔 재질보다 실리콘 하이드로겔 재질이 더 많은 영향을 받은 것으로 나타났다.
      번역하기

      목 적: 본 연구에서는 자외선 UV-A, UV-B, UV-C의 노출 증가에 따른 UV 차단용 소프트 콘택트렌즈의 시감투과율 및 대비감도의 변화에 미치는 영향에 대하여 연구하였다. 방 법: UV-A, UV-B, UV-C lamp...

      목 적: 본 연구에서는 자외선 UV-A, UV-B, UV-C의 노출 증가에 따른 UV 차단용 소프트 콘택트렌즈의 시감투과율 및 대비감도의 변화에 미치는 영향에 대하여 연구하였다.
      방 법: UV-A, UV-B, UV-C lamp의 영향을 받은 2개의 하이드로겔 렌즈, 2개의 실리콘 하이드로겔 렌즈의 시감투과율과 피검자 23명(46안)의 대비감도를 검사하였다.
      결 과: UV lamp에 영향을 받은 콘택트렌즈의 시감투과율이 UV-C 조사받은 렌즈가 가장 크게 감소하였으며 UV-B, UV-A순으로 감소하였다. 동일한 자외선 양(9.35mJ/cm2)을 조사 받은 소프트 콘택트렌즈로 피검사자에게 착용 후 대비감도를 측정값은 UV-C 조사 받는 소프트 콘택트렌즈가 가장 낮게 측정되었고, 이는 통계적으로 유의한 차이를 보였다(p<0.05).
      결 론: UV-A, UV-B, UV-C lamp의 영향을 받은 소프트 콘택트렌즈의 시감투과율 및 대비감도 변화는 UV-C, UV-B, UV-A lamp 순으로 영향을 많이 받는 것을 알 수 있었고, 하이드로겔 재질보다 실리콘 하이드로겔 재질이 더 많은 영향을 받은 것으로 나타났다.

      더보기

      참고문헌 (Reference)

      1 유동식, "콘택트렌즈의 광투과율 특성 평가" 한국안광학회 12 (12): 37-45, 2007

      2 Michael G Harris, "Ultraviolet transmittance of the vistakon disposable contact lenses" 23 : 10-15, 2000

      3 Linda Moore, "Ultraviolet (UV) transmittance characteristics of daily disposable and silicone hydrogel contact lenses" 29 (29): 115-122, 2006

      4 Michael G Harris, "Transmittance of Tinted and UV-Blocking Disposable Contact Lenses" 76 (76): 177-180, 1999

      5 Kluka D A, "The effects of daily-wear contact lenses upon contast sensitivity in selected professional and collegiate female tennis players" 64 (64): 182-186, 1993

      6 Vogler, Arnd, "Photooxidation of Coordinated dinitrogen. Photolysis of the ClO2 adduct of [(NH3)5Os(μ-N2)Os(NH3)5]5+" 18 : 73-74, 2012

      7 James E Walsh, "Novel Method for determining Hydrogel and Silicon hydrogel contact lens transmission curves and their spatially specific ultraviolet radiation protection factors" 33 (33): 58-64, 2007

      8 Hermann Faubl, "Methods for Determining Ultraviolet Transmission of UV-Blocking Contact Lenses" 25 : 142-148, 1998

      9 Russell LW, "Measuring contrast sensitivity with inappropriate optical correction" 20 : 442-451, 2000

      10 Woods RL, "Measuring contast sensitivity with inappropriate optical correction" 20 (20): 442-451, 2000

      1 유동식, "콘택트렌즈의 광투과율 특성 평가" 한국안광학회 12 (12): 37-45, 2007

      2 Michael G Harris, "Ultraviolet transmittance of the vistakon disposable contact lenses" 23 : 10-15, 2000

      3 Linda Moore, "Ultraviolet (UV) transmittance characteristics of daily disposable and silicone hydrogel contact lenses" 29 (29): 115-122, 2006

      4 Michael G Harris, "Transmittance of Tinted and UV-Blocking Disposable Contact Lenses" 76 (76): 177-180, 1999

      5 Kluka D A, "The effects of daily-wear contact lenses upon contast sensitivity in selected professional and collegiate female tennis players" 64 (64): 182-186, 1993

      6 Vogler, Arnd, "Photooxidation of Coordinated dinitrogen. Photolysis of the ClO2 adduct of [(NH3)5Os(μ-N2)Os(NH3)5]5+" 18 : 73-74, 2012

      7 James E Walsh, "Novel Method for determining Hydrogel and Silicon hydrogel contact lens transmission curves and their spatially specific ultraviolet radiation protection factors" 33 (33): 58-64, 2007

      8 Hermann Faubl, "Methods for Determining Ultraviolet Transmission of UV-Blocking Contact Lenses" 25 : 142-148, 1998

      9 Russell LW, "Measuring contrast sensitivity with inappropriate optical correction" 20 : 442-451, 2000

      10 Woods RL, "Measuring contast sensitivity with inappropriate optical correction" 20 (20): 442-451, 2000

      11 Lee YK, "Influence of Sun-expose on the Skin Aging" Graduate School of Distance Learning Sookmyung Woman's University 2007

      12 International Commission on Non-Ionizing Radiation Protection, "Guidelines on limits of exposure to ultraviolet radiation of wavelengths between 180 and 400nm(incoherent optical radiation)" 87 (87): 171-186, 2004

      13 Ozkanici A, "Do daily wear opaquely tinted hydrogel soft contact lenses affect contrast sensitivity fuction at one meter?" 29 (29): 48-49, 2003

      14 Karen S DeLoss, "Current silicon hydrogel UVR blocking lenses and their associated protection factors" 33 : 136-140, 2010

      15 Oen FT, "Contrast sensitivity in a large adult population" 23 : 322-326, 1995

      16 Gundel R E, "Change in contrast sensitivity induced by spherical hydrogel lenses on low astigmats" 59 : 636-640, 1988

      17 Oriowo OM, "Action spectrum and recovery for in vitro UV-induced cataract using whole lenses" 42 (42): 2596-2602, 2001

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2012-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.74 0.74 0.71
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.62 0.59 0.899 0.1
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼