      Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

      한글로보기

      https://www.riss.kr/link?id=A104532793

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. Materials and M...

      Purpose: To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume.
      Materials and Methods: For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis® software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson’s or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared.
      Results: Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume (γ= 0.637 for total liver and γ= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec).
      Conclusion: Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

      더보기

      참고문헌 (Reference)

      1 Akabayashi A, "The first donor death after living-related liver transplantation in Japan" 77 : 634-, 2004

      2 Strong RW, "Successful liver transplantation from a living donor to her son" 322 : 1505-1507, 1990

      3 Fan ST, "Safety of donors in live donor liver transplantation using right lobe grafts" 135 : 336-340, 2000

      4 Ploeg RJ, "Risk factors for primary dysfunction after liver transplantation--a multivariate analysis" 55 : 807-813, 1993

      5 Kim KW, "Right lobe estimated blood-free weight for living donor liver transplantation: accuracy of automated blood-free CT volumetry--preliminary results" 256 : 433-440, 2010

      6 Suzuki K, "Quantitative radiology: automated CT liver volumetry compared with interactive volumetry and manual volumetry" 197 : W706-W712, 2011

      7 Kawasaki S, "Preoperative measurement of segmental liver volume of donors for living related liver transplantation" 18 : 1115-1120, 1993

      8 Dubus L, "Orieux G, et al. Comparison of semi-automated and manual methods to measure the volume of liver tumours on MDCT images" 21 : 996-1003, 2011

      9 Okada T, "Nakamura H, et al. Automated segmentation of the liver from 3D CT images using probabilistic atlas and multilevel statistical shape model" 15 : 1390-1403, 2008

      10 Sandrasegaran K, "Measurement of liver volume using spiral CT and the curved line and cubic spline algorithms: reproducibility and interobserver variation" 24 : 61-65, 1999

      1 Akabayashi A, "The first donor death after living-related liver transplantation in Japan" 77 : 634-, 2004

      2 Strong RW, "Successful liver transplantation from a living donor to her son" 322 : 1505-1507, 1990

      3 Fan ST, "Safety of donors in live donor liver transplantation using right lobe grafts" 135 : 336-340, 2000

      4 Ploeg RJ, "Risk factors for primary dysfunction after liver transplantation--a multivariate analysis" 55 : 807-813, 1993

      5 Kim KW, "Right lobe estimated blood-free weight for living donor liver transplantation: accuracy of automated blood-free CT volumetry--preliminary results" 256 : 433-440, 2010

      6 Suzuki K, "Quantitative radiology: automated CT liver volumetry compared with interactive volumetry and manual volumetry" 197 : W706-W712, 2011

      7 Kawasaki S, "Preoperative measurement of segmental liver volume of donors for living related liver transplantation" 18 : 1115-1120, 1993

      8 Dubus L, "Orieux G, et al. Comparison of semi-automated and manual methods to measure the volume of liver tumours on MDCT images" 21 : 996-1003, 2011

      9 Okada T, "Nakamura H, et al. Automated segmentation of the liver from 3D CT images using probabilistic atlas and multilevel statistical shape model" 15 : 1390-1403, 2008

      10 Sandrasegaran K, "Measurement of liver volume using spiral CT and the curved line and cubic spline algorithms: reproducibility and interobserver variation" 24 : 61-65, 1999

      11 Henderson JM, "Measurement of liver and spleen volume by computed tomography. Assessment of reproducibility and changes found following a selective distal splenorenal shunt" 141 : 525-527, 1981

      12 Broering DC, "Living donor liver transplantation" 38 (38): S119-S135, 2003

      13 Hermoye L, "Liver segmentation in living liver transplant donors: comparison of semiautomatic and manual methods" 234 : 171-178, 2005

      14 Kiuchi T, "Impact of graft size mismatching on graft prognosis in liver transplantation from living donors" 67 : 321-327, 1999

      15 Sakamoto S, "Graft size assessment and analysis of donors for living donor liver transplantation using right lobe" 71 : 1407-1413, 2001

      16 Suzuki K, "Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms" 37 : 2159-2166, 2010

      17 Karlo C, "CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors" 75 : e107-e111, 2010

      18 Lemke AJ, "CT volumetry of the liver before transplantation" 166 : 18-23, 1997

      19 Vauthey JN, "Body surface area and body weight predict total liver volume in Western adults" 8 : 233-240, 2002

      20 Bae KT, "Automatic segmentation of liver structure in CT images" 20 : 71-78, 1993

      21 Gao L, "Automatic liver segmentation technique for three-dimensional visualization of CT data" 201 : 359-364, 1996

      22 Nakayama Y, "Automated hepatic volumetry for living related live transplantation at multisection CT" 240 : 743-748, 2006

      23 Hiroshige S, "Accurate preoperative estimation of liver-graft volumetry using three-dimensional computed tomography" 75 : 1561-1564, 2003

      24 Gondolesi GE, "Accurate method for clinical assessment of right lobe liver weight in adult living-related liver transplant" 36 : 1429-1433, 2004

      25 Heymsfield SB, "Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography" 90 : 185-187, 1979

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-11-24 학술지명변경 외국어명 : Journal of The Korean Radiological Society -> Journal of the Korean Society of Radiology (JKSR) KCI등재
      2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-09-15 학술지명변경 한글명 : 대한방사선의학회지 -> 대한영상의학회지 KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.1 0.1 0.07
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.06 0.05 0.258 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼