      Efficacy of 4-Haptic Bitoric Intraocular Lens Implantation in Asian Patients with Cataract and Astigmatism

      한글로보기

      https://www.riss.kr/link?id=A106029141

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To determine the efficacy of 4-haptic bitoric intraocular lens (IOL) implantation in Asian patients withcataract and astigmatism. Methods: A total of 19 eyes with ≤25.0 mm axial length and ≥0.75 diopters (D) corneal astigmatism wereinclud...

      Purpose: To determine the efficacy of 4-haptic bitoric intraocular lens (IOL) implantation in Asian patients withcataract and astigmatism.
      Methods: A total of 19 eyes with ≤25.0 mm axial length and ≥0.75 diopters (D) corneal astigmatism wereincluded in this prospective non-comparative study. All subjects underwent phacoemulsification with implantationof an AT Torbi 709M IOL. Visual and refractive outcomes as well as toric IOL axis were evaluatedduring a 3-month follow-up. Errors in predicted residual spherical equivalent were calculated by subtractingpredicted residual spherical equivalent from postoperative refraction.
      Results: Uncorrected and corrected distance visual acuity improved significantly 3 months after surgery, from0.43 to 0.05 and from 0.24 to -0.05, respectively. Mean refractive cylinders also decreased significantly, from-1.91 preoperatively to -0.54 D 3 months after surgery. Mean J0 and J45 decreased 3 months postoperatively,from 0.26 to 0.03 D and from 0.24 to -0.06 D, respectively. After 3 months, mean absolute IOL rotationwas 1.81º. Errors in predicted residual spherical equivalent showed a hyperopic shift of 0.35 D.
      Conclusions: Implantation of 4-haptic bitoric IOL proved to be effective for correcting astigmatism in Asianeyes during cataract surgery.

      더보기

      참고문헌 (Reference)

      1 Kessel L, "Toric intraocular lenses in the correction of astigmatism during cataract surgery : a systematic review and meta-analysis" 123 : 275-286, 2016

      2 Kim JH, "The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in Asians" 36 : 238-244, 2008

      3 Buckhurst PJ, "Surgical correction of astigmatism during cataract surgery" 93 : 409-418, 2010

      4 Thibos LN, "Power vector analysis of the optical outcome of refractive surgery" 27 : 80-85, 2001

      5 Patel CK, "Postoperative intraocular lens rotation : a randomized comparison of plate and loop haptic implants" 106 : 2190-2195, 1999

      6 Jampaulo M, "Long-term Staar toric intraocular lens rotational stability" 146 : 550-553, 2008

      7 Ouchi M, "High-cylinder toric intraocular lens implantation versus combined surgery of low-cylinder intraocular lens implantation and limbal relaxing incision for high-astigmatism eyes" 8 : 661-667, 2014

      8 Zhu X, "Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses" 100 : 263-268, 2016

      9 Kim MJ, "Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system : Influence of pupil size, decentration, and rotation" 41 : 2274-2282, 2015

      10 Pan CW, "Ethnic variation in central corneal refractive power and steep cornea in Asians" 21 : 99-105, 2014

      1 Kessel L, "Toric intraocular lenses in the correction of astigmatism during cataract surgery : a systematic review and meta-analysis" 123 : 275-286, 2016

      2 Kim JH, "The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in Asians" 36 : 238-244, 2008

      3 Buckhurst PJ, "Surgical correction of astigmatism during cataract surgery" 93 : 409-418, 2010

      4 Thibos LN, "Power vector analysis of the optical outcome of refractive surgery" 27 : 80-85, 2001

      5 Patel CK, "Postoperative intraocular lens rotation : a randomized comparison of plate and loop haptic implants" 106 : 2190-2195, 1999

      6 Jampaulo M, "Long-term Staar toric intraocular lens rotational stability" 146 : 550-553, 2008

      7 Ouchi M, "High-cylinder toric intraocular lens implantation versus combined surgery of low-cylinder intraocular lens implantation and limbal relaxing incision for high-astigmatism eyes" 8 : 661-667, 2014

      8 Zhu X, "Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses" 100 : 263-268, 2016

      9 Kim MJ, "Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system : Influence of pupil size, decentration, and rotation" 41 : 2274-2282, 2015

      10 Pan CW, "Ethnic variation in central corneal refractive power and steep cornea in Asians" 21 : 99-105, 2014

      11 Bascaran L, "Efficacy and stability of AT TORBI 709 M toric IOL" 29 : 194-199, 2013

      12 Li Y, "Effect of hydrophobic acrylic versus hydrophilic acrylic intraocular lens on posterior capsule opacification : meta-analysis" 8 : e77864-, 2013

      13 Chang DF, "Early rotational stability of the longer Staar toric intraocular lens : fifty consecutive cases" 29 : 935-940, 2003

      14 Yoon JJ, "Demographics and ocular biometric characteristics of patients undergoing cataract surgery in Auckland, New Zealand" 44 : 106-113, 2016

      15 Mamalis N, "Comparison of two plate-haptic intraocular lenses in a rabbit model" 22 (22): 1291-1295, 1996

      16 Mencucci R, "Clinical outcomes and rotational stability of a 4-haptic toric intraocular lens in myopic eyes" 40 : 1479-1487, 2014

      17 Kretz FT, "Clinical outcomes and capsular bag stability of a four-point haptic bitoric intraocular lens" 31 : 431-436, 2015

      18 Sheppard AL, "Clinical outcomes after implantation of a new hydrophobic acrylic toric IOL during routine cataract surgery" 39 : 41-47, 2013

      19 Tehrani M, "Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation" 29 : 2127-2134, 2003

      20 Hoffer KJ, "Biometry of 7, 500 cataractous eyes" 90 : 360-368, 1980

      21 Toto L, "Astigmatism correction with toric IOL : analysis of visual performance, position, and wavefront error" 29 : 476-483, 2013

      22 Novis C, "Astigmatism and toric intraocular lenses" 11 : 47-50, 2000

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2020-01-01 평가 등재학술지 선정 (재인증) KCI등재
      2019-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2007-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.11 0.11 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.1 0.13 0.482 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼