      Perfusion CT of the brain using 40-mm-wide detector and toggling table technique for initial imaging of acute stroke.

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>OBJECTIVE: Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an...

      <P>OBJECTIVE: Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an emergent clinical setting. MATERIALS AND METHODS: Fifty-eight patients who underwent 80-mm-coverage perfusion CT within 24 hours after stroke onset were included. Perfusion CT was performed using a 64-MDCT unit equipped with 40-mm-wide detector and the toggling table technique. Lesion detection by perfusion CT was analyzed using follow-up diffusion-weighted imaging and MR angiography as the reference standards. More conventional 20-mm-coverage perfusion CT was simulated by extracting data obtained at the basal ganglia level for comparison with 80-mm-coverage perfusion CT. RESULTS: Fifty-one patients had acute infarctions and seven patients did not. For 80-mm-coverage perfusion CT, perfusion abnormality was detected in 42 of 51 patients (sensitivity, 82.4%; and specificity, 85.7%). When patients with small artery disease (small acute infarctions in the basal ganglia, thalamus, corona radiata, and pons) were excluded, sensitivity increased to 92.3%. As compared with 80-mm-coverage perfusion CT, 20-mm-coverage perfusion CT missed nine acute infarctions located above or below the level of the basal ganglia (p = 0.0039). CONCLUSION: Perfusion CT with 80-mm-coverage was found to be useful as an initial imaging method in acute ischemic stroke, although it had low sensitivity for detecting small acute infarctions. In particular, this technique provided higher lesion detection than 20-mm-coverage perfusion CT.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼