RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Simultaneous Detection of Glabridin, (−)-α-Bisabolol, and Ascorbyl Tetraisopalmitate in Whitening Cosmetic Creams Using HPLC-PAD

      한글로보기

      https://www.riss.kr/link?id=A107608368

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>A simultaneous analytical method was developed and validated to quantify three lipophilic compounds; namely glabridin (an isoflavonoid isolated from crude licorice), (-)-alpha-bisabolol (a sesquiterpene alcohol obtained from plant extracts), ...

      <P>A simultaneous analytical method was developed and validated to quantify three lipophilic compounds; namely glabridin (an isoflavonoid isolated from crude licorice), (-)-alpha-bisabolol (a sesquiterpene alcohol obtained from plant extracts), and ascorbyl tetraisopalmitate (a fat-soluble molecule derived from vitamin C) in functional cosmetic cream using high-performance liquid chromatography (HPLC) coupled with photodiode array detection (PAD). Cosmetic cream samples were extracted with a mixture of acetonitrile and isopropyl alcohol (45:55, v/v) and the target compounds were separated on a C-18 column with a gradient mobile phase consisting of deionized water, acetonitrile, and isopropyl alcohol. The detector wavelengths were 228, 202, and 221 nm, for glabridin, (-)-alpha-bisabolol, and ascorbyl tetraisopalmitate, respectively. The calibration curves showed good linearity with determination coefficients (R (2)) a parts per thousand yen 0.999. The mean recoveries were ranged between 89.8 and 103.9 % with relative standard deviations (RSDs) < 5 %. The intra- and inter-day precision was < 2 %. The limits of detection (LODs) were 0.03, 0.4, and 4.02 mu g mL(-1) for glabridin, (-)-alpha-bisabolol, and ascorbyl tetraisopalmitate, respectively. The method was successfully applied for monitoring 11 market samples, in which glabridin was quantified in the range of 17.5-25 mg 100 g(-1), (-)-alpha-bisabolol in the range of 25.1-677 mg 100 g(-1), and 140.6-291.5 mg 100 g(-1) for ascorbyl tetraisopalmitate. The proposed analytical method is simple, sensitive, and versatile and can be used for the quantification of lipophilic compounds in cosmetics in a single chromatographic run.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼