RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE

      Development and Verification of a Volume Sensor for Measuring Human Behavior

      한글로보기

      https://www.riss.kr/link?id=A103720169

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, a muscle volume sensor was developed to estimate the human behavior for its application to bioengineering and synchronous signal collection. The sensor is easily manufactured at a low cost. In addition, its wearability is good, and it c...

      In this study, a muscle volume sensor was developed to estimate the human behavior for its application to bioengineering and synchronous signal collection. The sensor is easily manufactured at a low cost. In addition, its wearability is good, and it can measure the human motion intent using a simple algorithm. This study tested the developed sensor, verified the test results, and applied the sensor to an actual wearable robot to further verify its effectiveness. The results of this study can allow the application of the sensor for a gait assistance device, to the upper and lower extremities, and to medical and industrial equipment.

      더보기

      참고문헌 (Reference)

      1 임하성, "경도계를 이용한 정상 한국인의 피부 경도 측정" 대한피부과학회 40 (40): 19-24, 2002

      2 Silver, F. H., "Viscoelastic properties of human skin and processed dermis" 7 (7): 18-23, 2001

      3 De Luca, C. J., "The Use of Surface Electromyography in Biomechanics" 13 (13): 135-163, 1997

      4 Steel, R. G. D., "Principles and Procedures of Statistics: A Biometrical Approach" McGraw- Hill 187-, 1960

      5 Fukunaga, T., "Muscle volume is a major determinant of joint torque in human" 172 (172): 249-255, 2001

      6 Moromugi, S., "Muscle stiffness sensor to control an assistance device for the disabled" 8 (8): 42-45, 2004

      7 Bien, Z. Z., "Intention reading is essential in human-friendly interfaces for the elderly and the handicapped" 52 (52): 1500-1505, 2005

      8 Kiguchi, K., "EMG-based Neurofuzzy control of a 4DOF upper-limb power-assist exoskeleton" 3040-3043, 2007

      9 Moromugi, S., "Device for assisting grasping function (2nd Report: maneuverability Evaluation)" 2665-2669, 2003

      10 Seo, A. R., "Development of muscle volume sensor for the measuring human behavior" 951-952, 2010

      1 임하성, "경도계를 이용한 정상 한국인의 피부 경도 측정" 대한피부과학회 40 (40): 19-24, 2002

      2 Silver, F. H., "Viscoelastic properties of human skin and processed dermis" 7 (7): 18-23, 2001

      3 De Luca, C. J., "The Use of Surface Electromyography in Biomechanics" 13 (13): 135-163, 1997

      4 Steel, R. G. D., "Principles and Procedures of Statistics: A Biometrical Approach" McGraw- Hill 187-, 1960

      5 Fukunaga, T., "Muscle volume is a major determinant of joint torque in human" 172 (172): 249-255, 2001

      6 Moromugi, S., "Muscle stiffness sensor to control an assistance device for the disabled" 8 (8): 42-45, 2004

      7 Bien, Z. Z., "Intention reading is essential in human-friendly interfaces for the elderly and the handicapped" 52 (52): 1500-1505, 2005

      8 Kiguchi, K., "EMG-based Neurofuzzy control of a 4DOF upper-limb power-assist exoskeleton" 3040-3043, 2007

      9 Moromugi, S., "Device for assisting grasping function (2nd Report: maneuverability Evaluation)" 2665-2669, 2003

      10 Seo, A. R., "Development of muscle volume sensor for the measuring human behavior" 951-952, 2010

      11 Jeon, D. Y., "Design and control of an exoskeleton for the elderly and patients" IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC 11 : 428-432, 2006

      12 허필원, "Current Hand Exoskeleton Technologies for Rehabilitation and Assistive Engineering" 한국정밀공학회 13 (13): 807-824, 2012

      13 Sato, T., "Active understanding of human intention by a robot through monitoring of human behavior" 1 : 405-414, 1994

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-06-23 학회명변경 영문명 : Korean Society Of Precision Engineering -> Korean Society for Precision Engineering KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-05-30 학술지명변경 한글명 : 한국정밀공학회 영문논문집 -> International Journal of the Korean of Precision Engineering KCI등재후보
      2005-05-30 학술지명변경 한글명 : International Journal of the Korean of Precision Engineering -> International Journal of Precision Engineering and Manufacturing
      외국어명 : International Journal of the Korean of Precision Engineering -> International Journal of Precision Engineering and Manufacturing
      KCI등재후보
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.38 0.71 1.08
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.92 0.85 0.583 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼