When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic va...
When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.