      공동주택 실외기실 PVC 터닝도어의 단열 및 차음성능 개선

      한글로보기

      https://www.riss.kr/link?id=A109462501

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study focuses on improving the insulation and soundproofing performance of PVC turning doors used in the External Unit Rooms of apartment buildings. To enhance these properties, thermal analysis and in-house soundproofing tests were conducted, considering various influencing factors. The results were then verified through testing by an accredited institution. Thermal analysis revealed that the final model, with improved insulation, increased the indoor corner temperature by 3.4°C compared to the existing model. In the soundproofing test, the enhanced model showed an improvement of 5 dB in Rw+C over the existing model. Tests conducted by the accredited institution confirmed that the final product met insulation standards for the first region of the central area, which faces direct external air, as well as the condensation standard for region 1. Additionally, soundproofing performance improved to Rw+C 30 dB, an increase of 5 dB over the previous model. The door developed in this study is expected to maintain its insulation performance for the first region in the central area and condensation region 1, even with the grill open during winter. It also ensures that the WHO's recommended indoor noise levels are met, even in environments with high-noise equipment.
      번역하기

      This study focuses on improving the insulation and soundproofing performance of PVC turning doors used in the External Unit Rooms of apartment buildings. To enhance these properties, thermal analysis and in-house soundproofing tests were conducted, co...

      This study focuses on improving the insulation and soundproofing performance of PVC turning doors used in the External Unit Rooms of apartment buildings. To enhance these properties, thermal analysis and in-house soundproofing tests were conducted, considering various influencing factors. The results were then verified through testing by an accredited institution. Thermal analysis revealed that the final model, with improved insulation, increased the indoor corner temperature by 3.4°C compared to the existing model. In the soundproofing test, the enhanced model showed an improvement of 5 dB in Rw+C over the existing model. Tests conducted by the accredited institution confirmed that the final product met insulation standards for the first region of the central area, which faces direct external air, as well as the condensation standard for region 1. Additionally, soundproofing performance improved to Rw+C 30 dB, an increase of 5 dB over the previous model. The door developed in this study is expected to maintain its insulation performance for the first region in the central area and condensation region 1, even with the grill open during winter. It also ensures that the WHO's recommended indoor noise levels are met, even in environments with high-noise equipment.