RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS SCIE

      Damage to the cuff of EMG tube at endotracheal intubation by using a lightwand -A case report-

      한글로보기

      https://www.riss.kr/link?id=A104351539

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Electromyogpraphic endotracheal tube (EMG tube) is a new device used to monitor recurrent laryngeal nerve integrity during thyroid surgery. The EMG tube has 2 pairs of electrodes on the surface of silicon-based tube reached to inner space of tube cuff...

      Electromyogpraphic endotracheal tube (EMG tube) is a new device used to monitor recurrent laryngeal nerve integrity during thyroid surgery. The EMG tube has 2 pairs of electrodes on the surface of silicon-based tube reached to inner space of tube cuff. We experienced an unusual endotracheal tube-related problem from the distinct structural feature of the EMG tube. In this case, we intubated a patient who had difficult airway with the EMG tube using a lightwand. After successful endotracheal intubation, we could not expand the pilot balloon and ventilate the patient effectively. We removed the EMG tube and found that one of electrodes of the EMG tube is bended and made a right angle with the long axis of the tube, and perforated the tube cuff. So we report this case to make anesthesia providers aware that much more attention is needed to use EMG tube during endotracheal intubation.

      더보기

      참고문헌 (Reference)

      1 Rao GS, "The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction" 103 : 1624-1625, 2006

      2 Horne SK, "Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy" 136 : 952-956, 2007

      3 Jeon YS, "Partial airway obstruction caused by dissection of a reinforced endotracheal tube" 24 : 983-984, 2007

      4 Nishiyama T, "Optimal length and angle of a new lightwand device (Trachlight)" 11 : 332-335, 1999

      5 Tose R, "Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia" 52 : 1218-1220, 2003

      6 Maino P, "Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways" 60 : 278-282, 2005

      7 Rice DH, "Intraoperative recurrent laryngeal nerve monitoring" 105 : 372-375, 1991

      8 Ito H, "Intraoperative monitoring of vagal nerve activity with wire electrodes" 50 : 1304-1305, 2006

      9 Gleich SJ, "Inability to ventilate while using a silicone-based endotracheal tube" 20 : 389-92, 2008

      10 Seegobin RD, "Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs" 288 : 965-8, 1984

      1 Rao GS, "The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction" 103 : 1624-1625, 2006

      2 Horne SK, "Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy" 136 : 952-956, 2007

      3 Jeon YS, "Partial airway obstruction caused by dissection of a reinforced endotracheal tube" 24 : 983-984, 2007

      4 Nishiyama T, "Optimal length and angle of a new lightwand device (Trachlight)" 11 : 332-335, 1999

      5 Tose R, "Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia" 52 : 1218-1220, 2003

      6 Maino P, "Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways" 60 : 278-282, 2005

      7 Rice DH, "Intraoperative recurrent laryngeal nerve monitoring" 105 : 372-375, 1991

      8 Ito H, "Intraoperative monitoring of vagal nerve activity with wire electrodes" 50 : 1304-1305, 2006

      9 Gleich SJ, "Inability to ventilate while using a silicone-based endotracheal tube" 20 : 389-92, 2008

      10 Seegobin RD, "Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs" 288 : 965-8, 1984

      11 Chen TH, "Does the suggested lightwand bent length fit every patient? The relation between bent length and patient's thyroid prominence-tomandibular angle distance" 98 : 1070-1076, 2003

      12 Evanina EY, "Case study involving suctioning of an electromyographic endotracheal tube" 73 : 111-113, 2005

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-11-27 학회명변경 한글명 : 대한마취과학회 -> 대한마취통증의학회 KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-07-20 학술지명변경 한글명 : 대한마취과학회지 -> Korean Journal of Anesthesiology KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.09 0.09 0.1
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.09 0.09 0.27 0.01
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼