RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      A double-knotted pulmonary artery catheter with large loop in the right internal jugular vein -A case report-

      한글로보기

      https://www.riss.kr/link?id=A105967645

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Knotting of a pulmonary artery catheter (PAC) is a rare, but well-known complication of pulmonary artery (PA) catheterization. We report a case of a double-knotted PAC with a large loop in a patient with hepatocellular carcinoma (HCC) undergoing liver...

      Knotting of a pulmonary artery catheter (PAC) is a rare, but well-known complication of pulmonary artery (PA) catheterization. We report a case of a double-knotted PAC with a large loop in a patient with hepatocellular carcinoma (HCC) undergoing liver transplantation, which has been rarely reported in the literature. A PAC was advanced under pressure wave form guidance. PAC insertion was repeatedly attempted and the PAC was inserted 80 cm deep even though PAC should be normally inserted 45 to 55 cm deep. However, since no wave change was observed, we began deflating and pulling the balloon. At the 30-cm mark, the PAC could no longer be pulled. Fluoroscopy confirmed knotting of the PAC after surgery (The loop-formed PAC was shown in right internal jugular vein); thus, it was removed. For safe PA catheterization, deep insertion or repeated attempts should be avoided when the catheter cannot be easily inserted into the pulmonary artery.
      If possible, the insertion of PACs can be performed more safely by monitoring the movement of the catheter under fluoroscopy or transesophageal echocardiography.

      더보기

      참고문헌 (Reference)

      1 Bossert T, "Swan-Ganz catheter-induced severe complications in cardiac surgery:right ventricular perforation, knotting, and rupture of a pulmonary artery" 21 : 292-295, 2006

      2 Colbert S, "Swan Ganz catheter--all in a knot" 14 : 518-520, 1997

      3 Starzyk L, "Snaring swans : intraoperative knotting of pulmonary artery catheters" 48 : 66-70, 2016

      4 Karanikas ID, "Removal of knotted intravascular devices. Case report and review of the literature" 23 : 189-194, 2002

      5 Lapinsky SE, "Pro/con clinical debate : pulmonary artery catheters increase the morbidity and mortality of intensive care unit patients" 7 : 101-103, 2003

      6 Böttiger BW, "Non-surgical removal of a knotted Swan-Ganz catheter" 40 : 682-686, 1991

      7 Georghiou GP, "Knotting of a pulmonary artery catheter in the superior vena cava: surgical removal and a word of caution" 90 : e28-, 2004

      8 Fibuch EE, "Intracardiac knotting of a flow-directed balloon-tipped catheter" 59 : 217-212, 1980

      9 Hadian M, "Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters" 14 : R212-, 2010

      10 Evans DC, "Complications associcated with pulmonary artery catheters : a comprehensive clinical review" 98 : 199-208, 2009

      1 Bossert T, "Swan-Ganz catheter-induced severe complications in cardiac surgery:right ventricular perforation, knotting, and rupture of a pulmonary artery" 21 : 292-295, 2006

      2 Colbert S, "Swan Ganz catheter--all in a knot" 14 : 518-520, 1997

      3 Starzyk L, "Snaring swans : intraoperative knotting of pulmonary artery catheters" 48 : 66-70, 2016

      4 Karanikas ID, "Removal of knotted intravascular devices. Case report and review of the literature" 23 : 189-194, 2002

      5 Lapinsky SE, "Pro/con clinical debate : pulmonary artery catheters increase the morbidity and mortality of intensive care unit patients" 7 : 101-103, 2003

      6 Böttiger BW, "Non-surgical removal of a knotted Swan-Ganz catheter" 40 : 682-686, 1991

      7 Georghiou GP, "Knotting of a pulmonary artery catheter in the superior vena cava: surgical removal and a word of caution" 90 : e28-, 2004

      8 Fibuch EE, "Intracardiac knotting of a flow-directed balloon-tipped catheter" 59 : 217-212, 1980

      9 Hadian M, "Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters" 14 : R212-, 2010

      10 Evans DC, "Complications associcated with pulmonary artery catheters : a comprehensive clinical review" 98 : 199-208, 2009

      11 Swan HJ, "Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter" 283 : 447-451, 1970

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2017-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2015-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.02 0.02 0.03
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.04 0.04 0.21 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼