RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI우수등재 SCOPUS

      겨울철 주택내 유기화합물 공기오염농도에 관한 측정연구  :  서울시내 96채의 주택을 대상으로 In case of 96 houses in Seoul = Measurement Study on Indoor Organic Compounds Air Pollution in Winter

      한글로보기

      https://www.riss.kr/link?id=A45051098

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Measurements on indoor organic compounds air pollution level in 96 houses were conducted. Houses which measurement carried out were collected based on the survey results about house type and constructed year in Seoul city. Indoor air organic compounds...

      Measurements on indoor organic compounds air pollution level in 96 houses were conducted. Houses which measurement carried out were collected based on the survey results about house type and constructed year in Seoul city. Indoor air organic compounds were monitored with two diffusive samplers. One was a cartridge treated with 2,4-initrophenylhydrazine for aldehydes sampling. The other was a passive charcoal tube for VOCs sampling. Two samplers were simultaneously exposed in living room during 24 hours. Aldehydes extracted with 2ml acetonitrile from the cartridge were analyzed by HPLC equipped with an UV diode array detector. VOCs were extracted with 2ml carbon disulfide from the charcoal tube by shaking and then analyzed by chromatograph and mass selective detector. The main Results were as follows;
      1) Formaldehyde were detected in more than 90% of all homes, and average value of detected level was 54.92ppb. This alue is lower than ASHRAE guideline (100ppb) and WHO guideline (80ppb).
      2) Toluene were detected in all homes, and EthylAcetate, 1-Butanol, ethylbenzene, p-Xylene, D-limonen were detected more
      than 50% of all homes. 24 hours averaged level of sum of VOCs was 179.96㎍/㎥, and this value is lower than WHO‘s TVOC(Total Volatile Organic Compounds) guideline (300㎍/㎥).
      3) Mostly frequent detective level of formaldehyde was between 50-60㎍/㎥, and 84.09% of all homes showed lower level than WHO guideline.
      4) Mostly frequent detective level of sum of VOCs was between 100-150㎍/㎥, and 86.46% of all homes showed lower level than WHO's TVOCs guideline.

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼