<P><B>Abstract</B></P><P>The objective of this study is to demonstrate that a condition-monitoring system based on acoustic emission (AE) detection can provide timely detection of check valve degradation and service aging...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107534948
2006
-
SCI,SCIE,SCOPUS
학술저널
1411-1421(11쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P><B>Abstract</B></P><P>The objective of this study is to demonstrate that a condition-monitoring system based on acoustic emission (AE) detection can provide timely detection of check valve degradation and service aging...
<P><B>Abstract</B></P><P>The objective of this study is to demonstrate that a condition-monitoring system based on acoustic emission (AE) detection can provide timely detection of check valve degradation and service aging so that maintenance or replacement can be preformed prior to the loss of safety function. This research is focused on the investigation and understanding of the capability of the acoustic emission technique to provide diagnostic information on check valve failures.</P><P>AE testing for a check valve under controlled flow loop conditions was performed to detect and valve degradation such as wear and leakage due to foreign object interference. It is clearly demonstrated that the distinction of different types of failure were successful by systematically analyzing the characteristics of various AE parameters.</P>