      수배전계통의 여러 가지 고장조건에서 피뢰기에 흐르는 누설전류 = Leakage Currents Flowing through Lightning Surge Arresters under Various Fault Conditions in Receiving and Distribution Power Systems

      한글로보기

      https://www.riss.kr/link?id=A103688461

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Unsymmetrical faults are classified into single line-to-ground faults, line-to-line faults, or double line-to-ground faults in receiving and distribution power systems. Many of overhead distribution-line faults are single line-to-ground faults, and li...

      Unsymmetrical faults are classified into single line-to-ground faults, line-to-line faults, or double line-to-ground faults in receiving and distribution power systems. Many of overhead distribution-line faults are single line-to-ground faults, and lightning surge arresters are stressed by system frequency overvoltages due to unsymmetrical faults. In this work, the unsymmetrical faults in receiving and distribution systems were experimentally simulated, and the characteristics of total leakage current flowing through lightning surge arresters due to various unsymmetrical faults were investigated. As a result, a little variations of the leakage current flowing through Zinc oxide (ZnO) surge arresters in the range of $\pm$10[%] voltage regulations were observed. It could be concluded that the unsymmetrical faults have no effect on the long-term life performance of ZnO surge arresters in effective grounding systems. On the other hand, the magnitude of the leakage current flowing through ZnO surge arrester elements under single line-to-ground faults was more than 140 times as compared with that under normal operating voltages in ineffective grounding systems. But abnormal voltages caused by line-to-line faults and double line-to-ground faults have a little effect on total leakage current of ZnO surge arrester elements.

      더보기

      국문 초록 (Abstract)

      수배전계통의 고장에는 1선 지락, 선간 단락, 2선 지락 등의 고장이 있다. 가공 배전 계통에서 일어나는 대부분의 고장은 1선 지락이며, 피뢰기는 이러한 고장에 의한 빈번한 과전압에 의해 ...

      수배전계통의 고장에는 1선 지락, 선간 단락, 2선 지락 등의 고장이 있다. 가공 배전 계통에서 일어나는 대부분의 고장은 1선 지락이며, 피뢰기는 이러한 고장에 의한 빈번한 과전압에 의해 스트레스를 받는다. 본 논문에서는 수배전계통에서 일어날 수 있는 고장을 모의하여 여러 가지 고장에 의해 피뢰기에 흐르는 누설전류의 특성에 대하여 조사하였다. 결과적으로, $\pm$10[%] 범위의 전압변동률에 의해서 피뢰기에 흐르는 누설전류는 거의 변화가 없었다. 성능이 우수한 접지 시스템 하에서는 전압변동률은 피뢰기의 긴 시간동안의 동작에 별 영향을 줄 수가 없었다. 하지만, 1선 지락 고장에서 피뢰기에 흐르는 누설전류의 최대값은 비효과적인 접지 시스템의 운전 전압에서의 누설전류와 비교하였을 때 140배 이상이 되었다. 그러나 선간 단락과 2선 지락 고장의 경우에는 피뢰기의 누설전류에 거의 영향을 미치지 못했다.

      더보기

      참고문헌 (Reference)

      1 "Protection of Information and Communication Facilities against Lightning" Inha university 11-40, 2004.2.

      2 "New method for measurement of resistive leakage currents of metal-oxide surge arrester in service" 5 (5): 1990-, pp.1811-1822

      3 "Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arresters" 51c (51c): 253 -259, 2002.

      4 "Degradation of ZnO based surge arresters under field conditions" 143 (143): 291-297, 1996.

      5 "A procedure for estimating the life time of gapless metal oxide surge arresters for AC application" no. 2 : 1986-, pp.67-74

      6 "A Monitoring Device of Leakage Currents Flowing through ZnO Surge Arresters" 42 (42): 1568-1574, 2003.

      7 "A Detection Method of Resistive Leakage Current Flowing through ZnO Arrester Blocks" 15 (15): 67 -73, 2001.

      8 "?Hd?H?H?Hn?H?H?HZ?Hp?Hv?HZ ??Hp" ?H?H?H?H?Ho?H?H ?H`? 134-152, 2000.1.

      9 "?Hd?H?H?HB?H?H?HH?H{" ?H?H?H?H?H?H?H?H?H?H 138-140, 2001.2.

      1 "Protection of Information and Communication Facilities against Lightning" Inha university 11-40, 2004.2.

      2 "New method for measurement of resistive leakage currents of metal-oxide surge arrester in service" 5 (5): 1990-, pp.1811-1822

      3 "Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arresters" 51c (51c): 253 -259, 2002.

      4 "Degradation of ZnO based surge arresters under field conditions" 143 (143): 291-297, 1996.

      5 "A procedure for estimating the life time of gapless metal oxide surge arresters for AC application" no. 2 : 1986-, pp.67-74

      6 "A Monitoring Device of Leakage Currents Flowing through ZnO Surge Arresters" 42 (42): 1568-1574, 2003.

      7 "A Detection Method of Resistive Leakage Current Flowing through ZnO Arrester Blocks" 15 (15): 67 -73, 2001.

      8 "?Hd?H?H?Hn?H?H?HZ?Hp?Hv?HZ ??Hp" ?H?H?H?H?Ho?H?H ?H`? 134-152, 2000.1.

      9 "?Hd?H?H?HB?H?H?HH?H{" ?H?H?H?H?H?H?H?H?H?H 138-140, 2001.2.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2015-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2014-01-08 학술지명변경 외국어명 : 미등록 -> Journal of the Korean Institute of Illuminating and Electrical Installation Engineers KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.17 0.17 0.19
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.18 0.17 0.342 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼