RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Comparisons of Test- Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

      한글로보기

      https://www.riss.kr/link?id=A106287163

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures....

      Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

      더보기

      참고문헌 (Reference)

      1 윤태림, "Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion" 대한물리치료학회 29 (29): 145-151, 2017

      2 Trendelenburg F., "Ueber den Gang bei angeborener Hüftgelenksluxation" 21 (21): 21-24, 1895

      3 Arnold CM, "The reliability and validity of handheld dynamometry for the measurement of lower-extremity muscle strength in older adults" 24 (24): 815-824, 2010

      4 Kendall KD, "The relationship between hip-abductor strength and the magnitude of pelvic drop in patients with low back pain" 19 (19): 422-435, 2010

      5 고은경, "The Reliability of Flexor Hallucis Longus Stretch Test in Subjects with Asymmetric Hallux Valgus Angles" 대한물리치료학회 28 (28): 124-127, 2016

      6 Desmyttere G, "Test-retest reliability of a hip strength assessment system in varsity soccer players" 37 (37): 138-143, 2019

      7 Agre JC, "Strength testing with a portable dynamometer: reliability for upper and lower extremities" 68 (68): 454-458, 1987

      8 Schwartz S, "Relationship between two measures of upper extremity strength: manual muscle test compared to hand-held myometry" 73 : 1063-1068, 1992

      9 Krause DA, "Influence of lever arm and stabilization on measures of hip abduction and adduction torque obtained by hand-held dynamometry" 88 (88): 37-42, 2007

      10 McBeth JM, "Hip muscle activity during 3 side-lying hip-strengthening exercises in distance runners" 47 (47): 15-23, 2012

      1 윤태림, "Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion" 대한물리치료학회 29 (29): 145-151, 2017

      2 Trendelenburg F., "Ueber den Gang bei angeborener Hüftgelenksluxation" 21 (21): 21-24, 1895

      3 Arnold CM, "The reliability and validity of handheld dynamometry for the measurement of lower-extremity muscle strength in older adults" 24 (24): 815-824, 2010

      4 Kendall KD, "The relationship between hip-abductor strength and the magnitude of pelvic drop in patients with low back pain" 19 (19): 422-435, 2010

      5 고은경, "The Reliability of Flexor Hallucis Longus Stretch Test in Subjects with Asymmetric Hallux Valgus Angles" 대한물리치료학회 28 (28): 124-127, 2016

      6 Desmyttere G, "Test-retest reliability of a hip strength assessment system in varsity soccer players" 37 (37): 138-143, 2019

      7 Agre JC, "Strength testing with a portable dynamometer: reliability for upper and lower extremities" 68 (68): 454-458, 1987

      8 Schwartz S, "Relationship between two measures of upper extremity strength: manual muscle test compared to hand-held myometry" 73 : 1063-1068, 1992

      9 Krause DA, "Influence of lever arm and stabilization on measures of hip abduction and adduction torque obtained by hand-held dynamometry" 88 (88): 37-42, 2007

      10 McBeth JM, "Hip muscle activity during 3 side-lying hip-strengthening exercises in distance runners" 47 (47): 15-23, 2012

      11 Cynn HS, "Effects of lumbar stabilization using a pressure biofeedback unit on muscle activity and lateral pelvic tilt during hip abduction in sidelying" 87 (87): 1454-1458, 2006

      12 박정주, "Effects of Gluteus Medius Strengthening Training Using Pressure Biofeedback Unit for Muscle Function and Balance in Stroke Patients" 대한물리치료학회 27 (27): 221-227, 2015

      13 Sahrmann SA, "Diagnosis and treatment of movement impairment syndromes" Mosby 2002

      14 Widler KS, "Assessment of hip abductor muscle strength. A validity and reliability study" 91 (91): 2666-2672, 2009

      15 Crossley KM, "Analysis of outcome measures for persons with patellofemoral pain: Which are reliable and valid?" 85 (85): 815-822, 2004

      16 Stratford PW, "A comparison of make and break tests using a hand-held dynamometer and the Kin-Com" 19 (19): 28-32, 1994

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2028 평가예정 재인증평가 신청대상 (재인증)
      2022-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2019-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2015-03-31 학회명변경 영문명 : The Korean Society of Physical Therapy -> The Journal of Korean Physical Therapy KCI등재
      2012-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2011-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2010-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2008-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2007-07-06 학회명변경 영문명 : The Korean Society Of Physical Therapy -> The Korean Society of Physical Therapy
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.89 0.89 0.78
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.72 0.67 0.431 0.22
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼