      In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressureloss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure lossincreased wit...

      In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressureloss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure lossincreased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressureloss of the reel hose per unit length was estimated to be .13~.15 ㎏f/㎠. Third, in the pressure loss experiment accordingto the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (ΔP~Q2), in the piping flow.
      These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting designof fire hose reel hydrants used in buildings.

      더보기

      국문 초록 (Abstract)

      본 연구에서는 호스릴옥내소화전의 압력손실 실험을 실시한 후 각 요소의 압력 손실에 미치는 영향을 비교·분석하였다. 첫째, 호스릴옥내소화전의 호스릴 길이에 따른 압력손실 실험에서, ...

      본 연구에서는 호스릴옥내소화전의 압력손실 실험을 실시한 후 각 요소의 압력 손실에 미치는 영향을 비교·분석하였다. 첫째, 호스릴옥내소화전의 호스릴 길이에 따른 압력손실 실험에서, 호스릴의 길이가 길어짐에 따라 압력 손실이 증가하였으며, 이는 25 m 호스를 기준으로 일반 옥내소화전 호스에 비하여 38.86% 만큼 압력손실이 증가하는것을 알 수 있었다. 둘째, 단위 길이 당 호스릴의 압력손실은 .13~.15 ㎏f/㎠으로 측정되었다. 셋째, 유량의 변화에 따른 압력손실 실험에서는 일반 배관 유동에서의 유량-압력손실 관계(ΔP~Q2)와 유사한 결과를 얻을 수 있었다. 이 연구 결과는 호스릴옥내소화전이 사용되는 건축물에 펌프의 양정계산, 호스릴옥내소화전의 성능위주소방설계에 기초자료로 활용될 수 있을 것이다.

      더보기

      참고문헌 (Reference)

      1 민세홍, "화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구" 한국화재소방학회 27 (27): 52-59, 2013

      2 Y. K. Hwang, "Applicability of the CFD for Pressure Drops in the Fire Reel Hose" Korean Institute of Fire Science & Engineering 261-262, 2017

      3 C. S. Baek, "A Experimental Study on the Performance Characteristics of Hose Reel for Indoor Hydrant Proportioner" Korean Institute of Fire Science & Engineering 209-216, 2003

      4 J. S. Nam, "A Comparative Study of the Performance for Hose Reel Hydrant System and Indoor Hydrant System" Korean Institute of Fire Science & Engineering 104-107, 2008

      1 민세홍, "화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구" 한국화재소방학회 27 (27): 52-59, 2013

      2 Y. K. Hwang, "Applicability of the CFD for Pressure Drops in the Fire Reel Hose" Korean Institute of Fire Science & Engineering 261-262, 2017

      3 C. S. Baek, "A Experimental Study on the Performance Characteristics of Hose Reel for Indoor Hydrant Proportioner" Korean Institute of Fire Science & Engineering 209-216, 2003

      4 J. S. Nam, "A Comparative Study of the Performance for Hose Reel Hydrant System and Indoor Hydrant System" Korean Institute of Fire Science & Engineering 104-107, 2008

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-09-03 학술지명변경 외국어명 : JOURNAL OF KOREAN INSTITUTE OF FIRE SCIENCE & ENGINEERING -> Fire Science and Engineering KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-10-10 학술지명변경 한글명 : 화재.소방학회지 -> 한국화재소방학회 논문지 KCI등재
      2008-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2007-07-02 학술지명변경 외국어명 : TRANSACTION OF KOREAN INSTITUTE OF FIRE SCIENCE & ENGINEERING -> JOURNAL OF KOREAN INSTITUTE OF FIRE SCIENCE & ENGINEERING KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2002-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.45 0.45 0.46
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.44 0.45 0.613 0.18
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼