RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Thermo-mechanical behavior of cast-in-place energy piles

      한글로보기

      https://www.riss.kr/link?id=A107454139

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P>An energy pile induces heat exchange with the ground formation by circulating heat carrier fluid through a heat exchange pipe, which is encased in pile foundation. During heat exchange, temperature variation in energy pile generates thermally-induced stress due to the different thermo-mechanical behavior between the pile and surrounding ground, and the restriction of pile deformation. A series of full-scale field tests was performed to identify the thermo-mechanical behavior of a cast-in-place energy pile equipped with 5-pair-parallel U-type heat exchange pipe. During the field investigation, each cooling and heating test lasted for 30 days, including a 15-day operating period and 15-day resting period, and the thermal stress generated in the energy pile was monitored. The maximum thermal stress was evaluated to be 2.6 MPa in the cooling test, which is about 10% of the design compressive strength of concrete. In addition, a finite element (FE) numerical model was developed to simulate the thermo-mechanical behavior of the energy pile. In the numerical analysis, relevant boundary conditions and interface model were determined by comparing with the field measurement. Finally, a parametric study was performed to estimate the thermal stress and deformation of a cast-in-place energy pile for various ground conditions.</P> <P><B>Highlights</B></P> <P> <UL> <LI> A large-diameter cast-in-place concrete energy pile was constructed in a test bed. </LI> <LI> The maximum thermal stress was evaluated to be 2.6 MPa in the cooling test. </LI> <LI> This value is about 10% of the design compressive strength of concrete. </LI> <LI> A parametric study for the thermos-mechanical behavior of energy piles. </LI> </UL> </P>
      번역하기

      <P><B>Abstract</B></P> <P>An energy pile induces heat exchange with the ground formation by circulating heat carrier fluid through a heat exchange pipe, which is encased in pile foundation. During heat exchange, temperat...

      <P><B>Abstract</B></P> <P>An energy pile induces heat exchange with the ground formation by circulating heat carrier fluid through a heat exchange pipe, which is encased in pile foundation. During heat exchange, temperature variation in energy pile generates thermally-induced stress due to the different thermo-mechanical behavior between the pile and surrounding ground, and the restriction of pile deformation. A series of full-scale field tests was performed to identify the thermo-mechanical behavior of a cast-in-place energy pile equipped with 5-pair-parallel U-type heat exchange pipe. During the field investigation, each cooling and heating test lasted for 30 days, including a 15-day operating period and 15-day resting period, and the thermal stress generated in the energy pile was monitored. The maximum thermal stress was evaluated to be 2.6 MPa in the cooling test, which is about 10% of the design compressive strength of concrete. In addition, a finite element (FE) numerical model was developed to simulate the thermo-mechanical behavior of the energy pile. In the numerical analysis, relevant boundary conditions and interface model were determined by comparing with the field measurement. Finally, a parametric study was performed to estimate the thermal stress and deformation of a cast-in-place energy pile for various ground conditions.</P> <P><B>Highlights</B></P> <P> <UL> <LI> A large-diameter cast-in-place concrete energy pile was constructed in a test bed. </LI> <LI> The maximum thermal stress was evaluated to be 2.6 MPa in the cooling test. </LI> <LI> This value is about 10% of the design compressive strength of concrete. </LI> <LI> A parametric study for the thermos-mechanical behavior of energy piles. </LI> </UL> </P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼