RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      보존서고의 공기질 실태 조사 = A Survey of Indoor Air Quality in Archives

      한글로보기

      https://www.riss.kr/link?id=A100036927

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Archives are the indoor spaces which have the special purpose of preservation of records. But the values of the Korean standard about air quality in archives are not realistic. Furthermore there are no measured data for analysis about indoor air quali...

      Archives are the indoor spaces which have the special purpose of preservation of records. But the values of the Korean standard about air quality in archives are not realistic. Furthermore there are no measured data for analysis about indoor air quality level of archives. So, we measured indoor air quality of three archives on site for evaluation standard level. We carried comparative analyses of the Korean standard and ISO-11799 the international standard for review of the adequacy of standard. SO₂, O₃ and CO concentration levels in archives were much lower(about 10% level) than the Korean standard. PM10 and Formaldehyde concentrations were about 40% level of the Korean standard, and NOx was about 65% level. But, TVOCs concentration was exceed the standard value(400 μg/m³). Temperature and Relative humidity level were far off the standard range. SO₂, O₃ and CO standard values should be improved to the international standard levels for realistic regulation values. NOx and Formaldehyde regulation values in the Korean standard should be gradually improved to the international standard levels, and their concentration management methods should be researched at the same time. As TVOCs concentration levels were exceed the standard, it is necessary to control the indoor air quality more strictly. The thermo-hygrostat must be installed to control temperature and humidity in archives.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 보존서고 공기질 관리 기준
      • 3. 서고내 공기질 측정 방법
      • 4. 서고내 공기질 측정 결과 분석
      • Abstract
      • 1. 서론
      • 2. 보존서고 공기질 관리 기준
      • 3. 서고내 공기질 측정 방법
      • 4. 서고내 공기질 측정 결과 분석
      • 5. 결론
      • REFERENCES
      더보기

      참고문헌 (Reference)

      1 정선화, "조선왕조실록 밀랍본 복원기술연구(제1보) -재현밀랍지의 열화거동평가-" 한국펄프·종이공학회 39 (39): 56-62, 2007

      2 이철민, "서고환경의 실내공기질에 관한 연구" 한국실내환경학회 6 (6): 92-101, 2009

      3 ISO-11799 International Standard, "Information and documentat strage requirements for archive and library materials"

      4 T. D. Davies, "Indoor/Outdoor Ozone Concentrations at a Contemporary Art Gallery" 34 (34): 135-137,

      5 Norbert S. Bear, "Indoor air pollution : Effects on cultural historic materials" 4 : 9-20, 1985

      6 Ministry of Environment, Korea, "Indoor Air Quality Control In Publicly Used Facilities" ETC. Act 2014

      7 Ministry of Security and Public Administration, Korea, "Enforcement decree of the act on the management of public archives" 2010

      8 National Archives of Korea, "A Study on the aging properties of paper-records by air pollutants" 2013

      9 National Archives of Korea, "A Study on Environmental Improvement in a Stack Room Preserve Archive" 2008

      1 정선화, "조선왕조실록 밀랍본 복원기술연구(제1보) -재현밀랍지의 열화거동평가-" 한국펄프·종이공학회 39 (39): 56-62, 2007

      2 이철민, "서고환경의 실내공기질에 관한 연구" 한국실내환경학회 6 (6): 92-101, 2009

      3 ISO-11799 International Standard, "Information and documentat strage requirements for archive and library materials"

      4 T. D. Davies, "Indoor/Outdoor Ozone Concentrations at a Contemporary Art Gallery" 34 (34): 135-137,

      5 Norbert S. Bear, "Indoor air pollution : Effects on cultural historic materials" 4 : 9-20, 1985

      6 Ministry of Environment, Korea, "Indoor Air Quality Control In Publicly Used Facilities" ETC. Act 2014

      7 Ministry of Security and Public Administration, Korea, "Enforcement decree of the act on the management of public archives" 2010

      8 National Archives of Korea, "A Study on the aging properties of paper-records by air pollutants" 2013

      9 National Archives of Korea, "A Study on Environmental Improvement in a Stack Room Preserve Archive" 2008

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-09-23 학술지등록 한글명 : 한국생활환경학회지
      외국어명 : The Korean Society of Living Environmental System
      KCI등재후보
      2004-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.29 0.29 0.28
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.31 0.3 0.376 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼